Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Multimode exposed core fiber specklegram sensor

Texto completo
Autor(es):
Cabral, Thiago D. [1, 2] ; Fujiwara, Eric [2] ; Warren-Smith, Stephen C. [3, 4, 1, 5] ; Ebendorff-Heidepriem, Heike [3, 4, 5] ; Cordeiro, Cristiano M. B. [3, 4, 1, 6]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Univ Estadual Campinas, Gleb Wataghin Inst Phys, BR-13083859 Campinas - Brazil
[2] Univ Estadual Campinas, Sch Mech Engn, BR-13083860 Campinas - Brazil
[3] Univ Adelaide, Inst Photon & Adv Sensing, Adelaide, SA 5005 - Australia
[4] Univ Adelaide, Sch Phys Sci, Adelaide, SA 5005 - Australia
[5] Univ Adelaide, ARC Ctr Excellence Nanoscale BioPhoton, Adelaide, SA 5005 - Australia
[6] Ebendorff-Heidepriem, Heike, Univ Adelaide, ARC Ctr Excellence Nanoscale BioPhoton, Adelaide, SA 5005, Australia.Cabral, Thiago D., Univ Estadual Campinas, Gleb Wataghin Inst Phys, BR-13083859 Campinas - Brazil
Número total de Afiliações: 6
Tipo de documento: Artigo Científico
Fonte: OPTICS LETTERS; v. 45, n. 12 JUN 15 2020.
Citações Web of Science: 0
Resumo

The inception of photonic crystal fibers (PCFs) allowed for unprecedented tailoring of waveguide properties for specialty sensing probes. Exposed core microstructured fibers (ECFs) represent a natural evolution of the PCF design for practical liquid and gas sensing. Until now, to the best of our knowledge, only single-mode or few-modes ECFs have been explored. In this Letter, we demonstrate a highly multimode ECF with a lateral access that extends throughout the whole length of the fiber. The ECF is operated as a fiber specklegram sensor for assessing properties of fluids and interrogated using a simple and low-cost setup. The probe exhibits a refractive index resolution and sensitivity of at least 4.6 x 10(-4) refractive index units (RIUs) and -10.97 RIU-1, respectively. A maximum temperature resolution up to 0.017 degrees C with a -0.20 degrees C-1 temperature sensitivity over the 23 degrees C-28 degrees C range and a liquid level sensing resolution up to 0.12 mm with -0.015 mm(-1) sensitivity over the 0.0-50.0 mm bathed the length range in water. (C) 2020 Optical Society of America (AU)

Processo FAPESP: 18/10409-7 - Sensores Ópticos Avançados baseados em Fibras Ópticas
Beneficiário:Cristiano Monteiro de Barros Cordeiro
Linha de fomento: Bolsas no Exterior - Pesquisa
Processo FAPESP: 17/25666-2 - Desenvolvimento de sensor de fibra óptica para medição de sinais de miografia de força aplicado a interfaces humano-robô
Beneficiário:Eric Fujiwara
Linha de fomento: Auxílio à Pesquisa - Regular