Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do SciELO, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Filling Ability and Flow of Root Canal Sealers: A Micro-Computed Tomographic Study

Texto completo
Autor(es):
Jáder Camilo Pinto [1] ; Fernanda Ferrari Esteves Torres [2] ; Mariana Mena Barreto Pivoto-João [3] ; Joni Augusto Cirelli [4] ; Juliane Maria Guerreiro-Tanomaru [5] ; Mário Tanomaru-Filho [6]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Universidade Estadual Paulista. School of Dentistry. Department of Restorative Dentistry - Brasil
[2] Universidade Estadual Paulista. School of Dentistry. Department of Restorative Dentistry - Brasil
[3] Universidade Estadual Paulista. School of Dentistry. Department of Restorative Dentistry - Brasil
[4] Universidade Estadual Paulista. School of Dentistry. Department of Diagnosis and Surgery - Brasil
[5] Universidade Estadual Paulista. School of Dentistry. Department of Restorative Dentistry - Brasil
[6] Universidade Estadual Paulista. School of Dentistry. Department of Restorative Dentistry - Brasil
Número total de Afiliações: 6
Tipo de documento: Artigo Científico
Fonte: Brazilian Dental Journal; v. 31, n. 5, p. 499-504, 2020-11-02.
Resumo

Abstract This study evaluated by micro-computed tomography (μCT) the filling ability in curved root canals, besides the flow of AH Plus (AHP) and Neo MTA Plus (NMTAP) sealers using different methodologies. Mandibular molars mesial roots with two root canals and degree of curvature between 20° and 40° were selected. The specimens were prepared with the ProDesign R system up to size 35.05 and were filled with the sealers by a continuous wave of condensation technique, Thermo Pack II (n=12). The teeth were scanned using μCT after root canal preparation and obturation. The volumetric percentage of filling material and voids were calculated. Flow was evaluated based on ISO 6876/2012 (n=10). Flow and filling were also evaluated in μCT using a glass plate with a central cavity and four grooves from the central cavity (n=6). Flow was linearly calculated into the grooves. The central cavity filling (CCF) and lateral cavity filling (LCF) were calculated in mm³. Data were submitted to non-paired t test with a significance threshold at 5%. The percentage of filling and voids between the root canals filled with AHP or NMTAP was similar (p>0.05). NMTAP presented the lowest flow in conventional test (p<0.05). Using μCT, sealers had similar CCF, LCF and linear flow (p>0.05). In conclusion, NMTAP and AHP had similar filling ability in curved mesial root canals of mandibular molars without presence of isthmus. Although AHP presented better flow than NMTAP using ISO methodology, there was no difference between these materials regarding volumetric filling when evaluated by μCT. (AU)

Processo FAPESP: 16/00321-0 - Desenvolvimento de novas metodologias utilizando micro-CT para avaliação de propriedades físico-químicas de materiais reparadores e cimentos endodônticos
Beneficiário:Fernanda Ferrari Esteves Torres Carvalho
Modalidade de apoio: Bolsas no Brasil - Doutorado
Processo FAPESP: 18/19665-6 - Efeito da aquisição e análise das imagens em micro-CT na avaliação das diferentes etapas do tratamento endodôntico em molares inferiores
Beneficiário:Jáder Camilo Pinto
Modalidade de apoio: Bolsas no Brasil - Doutorado
Processo FAPESP: 17/19049-0 - Avaliação das etapas do tratamento de canais radiculares, e das propriedades físico-químicas e biológicas de materiais à base de silicato tricálcico
Beneficiário:Mario Tanomaru Filho
Modalidade de apoio: Auxílio à Pesquisa - Regular