Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Monitoring the quality of ethanol-based hand sanitizers by low-cost near-infrared spectroscopy

Texto completo
Autor(es):
Pasquini, Celio [1, 2] ; Hespanhol, Maria C. [3] ; Cruz, Kaique A. M. L. [3] ; Pereira, Alexandre F. [3]
Número total de Autores: 4
Afiliação do(s) autor(es):
[1] Univ Estadual Campinas UNICAMP, Inst Quim, Rua Monteiro Lobato 290, BR-13083862 Campinas, SP - Brazil
[2] Univ Fed Vicosa UFV, Dept Solos, Campus UFV, BR-36570900 Vicosa, MG - Brazil
[3] Univ Fed Vicosa UFV, Dept Quim, Campus UFV, BR-36570900 Vicosa, MG - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: Microchemical Journal; v. 159, DEC 2020.
Citações Web of Science: 0
Resumo

The use of near-infrared spectroscopy (NIRS) based on a low-cost portable instrument for monitoring the quality of the three major formulations of ethanol-based hand sanitizers used for prevention against CoVID-19 disease is described. The quality of the sanitizers was evaluated using two approaches. In the first, a qualitative method was developed to identify gross non-conformities, using NIR spectral data compression by principal components analysis and projection of the spectrum of the tested sample in the principal component space delimited by samples of sanitizers prepared in the laboratory. In the second, a quantitative method was designed to determine the active substance (ethanol) employing multivariate regression based on partial least squares. The results demonstrate that the first approach can be used to detect non-conformities in the sanitizer composition, mostly associated with incorrect ethanol content. The second explores the use of NIRS for determination of the ethanol content in the three formulations aiming the quality control of the sanitizer manufacturing process. The ethanol content can be determined with an absolute root mean square error of prediction (RMSEP) equal to 0.68% (m/m), 0.83% (m/m) and 1.0% (v/v) for the three formulations evaluated. The RMSEP was estimated as 1.3% (m/m) for the commercial products. The measurement protocol takes approximately 1 min and requires only about 120 mu L of a sample. Besides, NIRS was employed to compare the rate of volatilization of the ethanol in the different formulations, an important parameter concerning the efficacy of ethanol-based sanitizers. (AU)

Processo FAPESP: 14/50951-4 - INCT 2014: Tecnologias Analíticas Avançadas
Beneficiário:Celio Pasquini
Modalidade de apoio: Auxílio à Pesquisa - Temático