Biomechanical behavior of CAD/CAM cobalt-chromium and zirconia full-arch fixed prostheses

Texto completo
Autor(es):
Barbin, Thais [1] ; Silva, Leticia Del Rio [1] ; Veloso, Daniele Valente [1] ; Borges, Guilherme Almeida [1] ; Camacho Presotto, Anna Gabriella [1] ; Ricardo Barao, Valentim Adelino [1] ; Groppo, Francisco Carlos [2] ; Mesquita, Marcelo Ferraz [1]
Número total de Autores: 8
Afiliação do(s) autor(es):
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Prosthodont & Periodontol, Piracicaba - Brazil
[2] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Physiol Sci, Piracicaba - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF ADVANCED PROSTHODONTICS; v. 12, n. 6, p. 329-337, DEC 2020.
Citações Web of Science: 0
Resumo

PURPOSE. To verify the influence of computer-aided design/computer-aided manufacturing (CAD/CAM) implant-supported prostheses manufactured with cobalt-chromium (Co-Cr) and zirconia (Zr), and whether ceramic application, spark erosion, and simulation of masticatory cycles modify biomechanical parameters (marginal fit, screw-loosening torque, and strain) on the implant-supported system. MATERIALS AND METHODS. Ten full-arch fixed frameworks were manufactured by a CAD/CAM milling system with Co-Cr and Zr (n=5/group). The marginal fit between the abutment and frameworks was measured as stated by single-screw test. Screw-loosening torque evaluated screw stability, and strain analysis was explored on the implant-supported system. All analyses were performed at 3 distinct times: after framework manufacturing; after ceramic application in both materials' frameworks; and after the spark erosion in Co-Cr frameworks. Afterward, stability analysis was re-evaluated after 106 mechanical cycles (2 Hz/150-N) for both materials. Statistical analyses were performed by Kruskal-Wallis and Dunn tests (alpha=.05). RESULTS. No difference between the two materials was found for marginal fit, screw-loosening torque, and strain after framework manufacturing (P>.05). Ceramic application did not affect the variables (P>.05). Spark erosion optimized marginal fit and strain medians for Co-Cr frameworks (P<.05). Screw-loosening torque was significantly reduced by masticatory simulation (P<.05) regardless of the framework materials. CONCLUSION. Co-Cr and Zr frameworks presented similar biomechanical behavior. Ceramic application had no effect on the biomechanical behavior of either material. Spark erosion was an effective technique to improve Co-Cr biomechanical behavior on the implant-supported system. Screw-loosening torque was reduced for both materials after masticatory simulation. (AU)

Processo FAPESP: 17/16303-3 - Estudo comparativo de técnicas de confecção de próteses totais fixas maxilares implantossuportadas: planejamento, materiais, desajuste, torque de afrouxamento, cobertura estética, ciclagem mecânica e distribuição de tensões
Beneficiário:Marcelo Ferraz Mesquita
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 17/15297-0 - Estudo comparativo de técnicas de confecção de próteses totais fixas maxilares implantossuportadas tipo All-on-4: planejamento, materiais, desajuste, torque de afrouxamento, cobertura estética, ciclagem mecânica e distribuição de tensões
Beneficiário:Thaís Barbin