Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Radiotherapy Linear Accelerator-Based X-Ray Acoustic Imaging Using Linear Array Transducer and Its Relationship with Dose: Multidomain Simulation and In Vitro Experiments

Texto completo
Autor(es):
Sampaio, Diego R. T. [1] ; Yaly, Carolina C. [1] ; Pavoni, Juliana F. [1] ; Carneiro, Antonio A. O. [1] ; Pavan, Theo Z. [1]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Dept Fis, FFCLRP, Ave Bandeirantes, BR-3900 Monte Alegre do Sul, SP - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: Brazilian Journal of Physics; v. 51, n. 4, p. 1069-1078, AUG 2021.
Citações Web of Science: 0
Resumo

As x-ray acoustic imaging (XAI) moves towards the external beam radiation therapy (EBRT) environment, introducing new practical XAI dosimetry systems with clinical ultrasound scanner becomes a significant contribution, especially using noise reduction methods that can increase the typical low signal-to-noise ratio (SNR) of XA images. In addition, experimental validation of multidomain XAI simulation is of great importance for accurate dose estimation. Therefore, in the present study, a XAI system combining a clinical linear particle accelerator (LINAC) and a linear array transducer connected to a clinical ultrasound scanner was developed. The capability of acquiring XA signal and generating images was investigated with simulations and experiments. PENELOPE and k-wave environments were combined to simulate the XAI system, which was used to generate XA images of different metals and bone in a water tank. A Daubechies's wavelet denoise method was proposed to improve XAI's SNR, where a threefold improvement in SNR of XA image of the bone sample was achieved. The denoised XA experimental images agreed well with simulations in terms of spatial profiles and signal amplitude dose-response slope values, therefore validating the multidomain simulations. (AU)

Processo FAPESP: 15/05684-0 - Formação de imagem fotoacústica induzida por laser e raios-X
Beneficiário:Diego Ronaldo Thomaz Sampaio
Modalidade de apoio: Bolsas no Brasil - Doutorado
Processo FAPESP: 13/18854-6 - Imagens fotoacústicas e ultrassônicas para caracterização de tecidos viscoelásticos
Beneficiário:Theo Zeferino Pavan
Modalidade de apoio: Auxílio à Pesquisa - Jovens Pesquisadores