Efficiency of an air circulation decontamination device for micro-organisms using ultraviolet radiation

Texto completo
Autor(es):
Correa, T. Q. [1] ; Blanco, K. C. [1] ; Vollet-Filho, J. D. [1] ; Morais, V. S. [1] ; Trevelin, W. R. [2] ; Pratavieira, S. [1] ; Bagnato, V. S. [3, 1]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Sao Carlos Inst Phys, Av Trabalhador Sao Carlense 400, POB 369, Sao Carlos, SP - Brazil
[2] Unimed Sao Carlos, Sao Paulo, SP - Brazil
[3] Texas A&M Univ, College Stn, TX - USA
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: Journal of Hospital Infection; v. 115, p. 32-43, SEP 2021.
Citações Web of Science: 1
Resumo

Background: The concern with environmental security to avoid contamination of individuals was intensified with the crisis established by SARS-CoV-2. The COVID-19 pandemic has shown the necessity to create systems and devices capable of clearing the air in an environment of micro-organisms more efficiently. The development of systems that allow the removal of micro-droplets mainly originating from breathing or talking from the air was the motivation of this study. Aim: This article describes a portable and easy-to-operate system that helps to eliminate the droplets or aerosols present in the environment by circulating air through an ultraviolet-C (UV -C) reactor. Methods: An air circulation device was developed, and a proof-of-principle study was performed using the device against bacteria in simulated and natural environments. The microbiological analysis was carried out by the simple sedimentation technique. In order to compare the experimental results and the expected results for other micro-organisms, the reduction rate values for bacteria and viruses were calculated and compared with the experimental results based on technical parameters (clean air delivery rate (CADR) and air changes per hour (ACH)). Findings: Results showed that the micro-organisms were eliminated with high efficiency by the air circulation decontamination device, with reductions of 99.9% in the proof-of principle study, and 84-97% in the hospital environments study, contributing to reducing contamination of individuals in environments considered to present risk. Conclusion: This study resulted in a low-cost and relatively simple device, which was shown to be effective and safe, and could be replicated, especially in low-income countries, respecting the standards for air disinfection using UV-C technologies. (c) 2021 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved. (AU)

Processo FAPESP: 14/50857-8 - INCT 2014 - de Óptica Básica e Aplicada às Ciências da Vida
Beneficiário:Vanderlei Salvador Bagnato
Modalidade de apoio: Auxílio à Pesquisa - Temático
Processo FAPESP: 13/07276-1 - CEPOF - Centro de Pesquisa em Óptica e Fotônica
Beneficiário:Vanderlei Salvador Bagnato
Modalidade de apoio: Auxílio à Pesquisa - Centros de Pesquisa, Inovação e Difusão - CEPIDs