Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

All-optical real-time monitoring of air/vacuum valves in water pipeline systems using fiber Bragg gratings

Texto completo
Autor(es):
de Aquino, Genivaldo A. [1, 2] ; de F. L. De Lucca, Yvone [1, 3] ; Cabral, Thiago D. [4, 5] ; Lazari, Pedro M. [5] ; Martim, Andre L. S. S. [1] ; Fujiwara, Eric [4] ; Cordeiro, Cristiano M. B. [5] ; Filho, Jose G. Dalfre [1]
Número total de Autores: 8
Afiliação do(s) autor(es):
[1] Univ Estadual Campinas, Sch Civil Engn Architecture & Urban Design, Campinas - Brazil
[2] Sao Paulo State Sanitat Co SABESP, Sao Paulo - Brazil
[3] Sao Paulo State Water & Energy Dept DAEE, Sao Paulo - Brazil
[4] Univ Estadual Campinas, Sch Mech Engn, Campinas - Brazil
[5] Univ Estadual Campinas, Gleb Wataghin Inst Phys, Campinas - Brazil
Número total de Afiliações: 5
Tipo de documento: Artigo Científico
Fonte: Journal of the Brazilian Society of Mechanical Sciences and Engineering; v. 44, n. 1 JAN 2022.
Citações Web of Science: 0
Resumo

A novel strategy for online real-time remote monitoring of air/vacuum valves in water pipelines is proposed and validated. The sensing setup consists of a fiber Bragg grating operating as an optical strain gauge and embedded into a 3D-printed thermoplastic polyurethane casing, which is then fixed to the intake/exhaust port of an air/vacuum valve and allowed to bend in response to the airflow. Experimentation with a test bench simulating water adductor piping systems shows that the proposed strategy can detect and discriminate between air purge and intake events, measure their duration, and possibly quantify the volume of displaced air. The proposed all-optical setup was compared against an orifice plate approach, producing consistent results while being more compact, robust, reliable, and requiring a single fiber optic sensor to achieve all measurements, as opposed to the four or up electronic pressure sensors with the orifice plate. (AU)

Processo FAPESP: 19/12166-7 - Emprego da cavitação hidrodinâmica para degradação de cafeína em água
Beneficiário:José Gilberto Dalfré Filho
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 17/09921-2 - Determinação da correlação entre turbidez e concentração de sedimentos em suspensão e elaboração de um modelo de avaliação do transporte de sedimentos para o Rio Jundiaí - Bacia do PCJ
Beneficiário:ANDRÉ LUÍS SOTERO SALUSTIANO MARTIM
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 10/51522-9 - Instalação experimental para a caracterização dinâmica de válvulas ventosas
Beneficiário:José Gilberto Dalfré Filho
Modalidade de apoio: Auxílio à Pesquisa - Regular