Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Malignancy prediction of cutaneous and subcutaneous neoplasms in canines using B-mode ultrasonography, Doppler, and ARFI elastography

Texto completo
Autor(es):
Kniphoff da Cruz, Igor Cezar [1] ; Carneiro, Rafael Kretzer [1] ; de Nardi, Andrigo Barboza [1] ; Ramirez Uscategui, Ricardo Andres [2, 3] ; Bortoluzzi, Eduarda Mazzardo [4] ; Rossi Feliciano, Marcus Antonio [5, 1]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Univ Estadual Paulista, Via Acesso Prof Paulo Donato Castellane S-N, BR-14884900 Jaboticabal - Brazil
[2] Univ CES, Medellin - Colombia
[3] Univ Fed Vale do Jequitinhonha & Mucuri, Unai - Brazil
[4] Kansas State Univ, Manhattan, KS 66506 - USA
[5] Univ Fed Santa Maria, Santa Maria, RS - Brazil
Número total de Afiliações: 5
Tipo de documento: Artigo Científico
Fonte: BMC Veterinary Research; v. 18, n. 1 JAN 3 2022.
Citações Web of Science: 0
Resumo

Background Cutaneous and subcutaneous neoplasms are highly prevalent in dogs, ranging from benign to highly aggressive and metastatic lesions. The diagnosis is obtained through histopathology, however it is an invasive technique that may take a long time to obtain the result, delaying the beginning of the adequate treatment. Thus, there is a need for non-invasive tests that can help in the early diagnosis of this type of cancer. The aim of this study was to verify the accuracy of B-mode ultrasonography, Doppler, and ARFI elastography to predict malignancy in cutaneous and subcutaneous canine neoplasms. In addition, we aim to propose an ultrasonography evaluation protocol and perform the neoplasms characterization using these three proposed techniques. Results Twenty-one types of specific neoplasm were diagnosed, and using B-mode, we verified the association between heterogeneous echotexture, invasiveness, presence of hyperechoic spots, and cavity areas with malignancy. An increased pulsatility was verified in malignant neoplasms using Doppler (cut-off value > 0.93). When using the elastography, malignancy was associated with non-deformable tissues and shear wave velocity > 3.52 m/s. Evaluation protocols were proposed associating 4, 5, 6, or 7 malignancy predictive characteristics, and characterization was done for all tumors with at least two cases. Conclusions We concluded that ultrasonography methods are promising and effective in predicting malignancy in these types of tumors, and the association of methods can increase the specificity of the results. (AU)

Processo FAPESP: 19/15282-8 - EMU concedido no processo 17/14957-6: Siemens S2000
Beneficiário:Wilter Ricardo Russiano Vicente
Modalidade de apoio: Auxílio à Pesquisa - Programa Equipamentos Multiusuários
Processo FAPESP: 17/14957-6 - Estudo de novas biotécnicas para reprodução de caninos e pequenos ruminantes
Beneficiário:Wilter Ricardo Russiano Vicente
Modalidade de apoio: Auxílio à Pesquisa - Temático