In Vitro Quantitative Evaluation of Postprocessing Filter for Metal Artifact Reduction in Cone Beam Computed Tomography Images of Titanium and Zirconium Dioxide Implants

Texto completo
Autor(es):
Costa, Andre Luiz Ferreira ; Fardim, Karolina A. C. ; Mantoani, Jennifer M. ; Ricardo, Ana Lucia Franco ; Jardini, Maria Aparecida N. ; Orhan, Kaan ; Lopes, Sergio Lucio Pereira de Castro
Número total de Autores: 7
Tipo de documento: Artigo Científico
Fonte: BIOMED RESEARCH INTERNATIONAL; v. 2022, p. 9-pg., 2022-02-24.
Resumo

Objective. To evaluate a postprocessing filter of a new imaging-processing software for analysis of metal artifact reduction. Methods. Eight artificial edentulous mandibles (phantoms), where titanium and zirconium dioxide implants had been installed in four different regions (i.e., incisors, canine, premolars, and molars). CBCT volume was acquired, and then, four types of filters were applied to the images: BAR filter and Multi-CDT NR filter (e-Vol DX) and Sharpening Filters 1x and 2x (OnDemand). Artifact was assessed by measuring the standard deviation (SD) of the gray values of filtered and unfiltered images. The comparison between implant material, teeth, and filters was performed by using ANOVA, whereas multiple comparisons were performed by using Bonferroni's test. The level of significance adopted was 5%. Results. The results showing higher SD values, which suggests a worse image, were obtained with titanium implants compared to zirconium dioxide ones. With regard to the four filters used, it can be seen that the lowest SD values were obtained with BAR and Multi-CDT NR filters and the highest with Sharpening Filters 1x and 2x, with no statistical difference between them, except regarding the molar region in titanium implants. Conclusion. The highest SD values were seen in zirconium dioxide implants, mainly in the region of anterior teeth. The BAR filter was found to be the most effective as its SD value decreased significantly, indicating that the image quality was improved. (AU)

Processo FAPESP: 19/26170-6 - Avaliação do efeito de filtros de pós-processamento na quantificação de artefatos de implantes dentários em imagens de tomografia computadorizada de feixe cônico
Beneficiário:Jennifer Milhano Mantoani
Modalidade de apoio: Bolsas no Brasil - Iniciação Científica
Processo FAPESP: 19/00495-6 - Análise da comparativa da influência de filtros de pós-processamento e da variação dos parâmetros de aquisição na quantificação de artefatos metálicos em imagens de tomografia computadorizada de feixe cônico
Beneficiário:Sérgio Lúcio Pereira de Castro Lopes
Modalidade de apoio: Auxílio à Pesquisa - Regular