Busca avançada
Ano de início
Entree
Conteúdo relacionado
(Referência obtida automaticamente do SciELO, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

DETERMINATION OF TOTAL AND BIOACCESSIBLE ELEMENTS IN TEMPORARY ADHESIVE TATTOOS USED BY CHILDREN AND ADULTS

Texto completo
Autor(es):
André L. Squissato [1] ; Augusto T. S. del Claro [2] ; Riad D. Lourenço [3] ; Alexandre M. Fioroto [4] ; Angerson N. Nascimento [5] ; Rodrigo A. A. Muñoz [6]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Universidade Federal de Uberlândia. Instituto de Química - Brasil
[2] Universidade Federal de Uberlândia. Instituto de Química - Brasil
[3] Universidade Federal de São Paulo. Departamento de Química - Brasil
[4] Universidade de São Paulo. Faculdade de Ciências Farmacêuticas. Departamento de Alimentos e Nutrição Experimental - Brasil
[5] Universidade Federal de São Paulo. Departamento de Química - Brasil
[6] Universidade Federal de Uberlândia. Instituto de Química - Brasil
Número total de Afiliações: 6
Tipo de documento: Artigo Científico
Fonte: Química Nova; v. 45, n. 9, p. 1067-1074, 2022-12-19.
Resumo

The presence of bioaccessible potentially-toxic elements in five different brands of temporary tattoos (packaged with bubble gums) aimed at children and three product brands used by young and adult audiences were analyzed in accordance with the Brazilian Organization of Technical Standards (ABNT) and International Organization for Standardization (ISO) for toy’s safety standards. Bioaccessible barium, copper and strontium were found in the concentration range between 1.78-11.1 μg g-1, 0.0364-0.875 μg g-1, 0.155-9.9 μg g-1, respectively. Bioaccessible lead (2.6 ± 0.1 μg g-1 - 4.36 ± 0.06 μg g-1) and boron (2.14 ± 0.07 - 3.54 ± 0.07 μg g-1) were found in two samples whereas chromium (0.403 ± 0.004 μg g-1) in one sample aimed at children. Bioaccessible aluminum was found in six samples, mostly at products used by children. Other elements whose bioaccessibility was evaluated were Mo (< LOD), Cd (< LOD), V (0.148 ± 0.003 μg g-1) and Co (0.003 - 1.756 μg g-1). All samples met the upper limits permitted by the national toy safety standard, however, chromium, lead, cobalt and barium presented higher bioaccessibility levels than the allowed values by cosmetic regulation that controls products applied directly to the skin. (AU)

Processo FAPESP: 16/02603-2 - Avaliação de espécies de Ni e V em amostras de petróleo
Beneficiário:Angerson Nogueira Do Nascimento
Modalidade de apoio: Auxílio à Pesquisa - Regular