Direct magnetic sorbent sampling flame atomic absorption spectrometry (DMSS-FAAS) for highly sensitive determination of trace metals

Texto completo
Autor(es):
Costa, Lucimara Mendonca ; Borges, Fabricio Alves ; Cavalcanti, Marcello Henrique da Silva ; do Lago, Ayla Campos ; Tarley, Cesar Ricardo Teixeira ; Martins, Giovana de Fatima Lima ; Figueiredo, Eduardo Costa
Número total de Autores: 7
Tipo de documento: Artigo Científico
Fonte: Analytica Chimica Acta; v. 1251, p. 11-pg., 2023-02-26.
Resumo

A procedure of direct magnetic sorbent sampling in flame atomic absorption spectrometry (DMSS-FAAS) was developed in this work. Metal-loaded magnetic sorbents were directly inserted in the flame of the FAAS for direct metal desorption/atomization. Magnetic graphene oxide aerogel (M-GOA) particles were synthesized, characterized, and used as a proof-of-concept in the magnetic dispersive solid phase extraction of Pb2+ ions from water samples. M-GOA was selected because is a light and porous sorbent, with high adsorption capacity, that is quickly burned by the flame. Magnetic particles were directly inserted in the flame by using a metallic magnetic probe, thereby avoiding the need for a chemical elution step. As all the extracted Pb2+ ions arrive to the flame without passing through the nebulization system, a drastic increase in the analytical signal was achieved. The improvement in the sensitivity of the proposed method (DMSS-FAAS) for Pb2+ determination was at least 40 times higher than the conventional procedure in which the Pb2+ is extracted, eluted, and analyzed by conventional flame atomic absorption spectrometry (FAAS) via the nebulization system. The analytical curve was linear from 5.0 to 180.0 mu g L-1 and the limit of detection was found to be 1.30 mu g L-1. Background measurements were insignificant, and the atomic absorption peaks were narrow and reproducible. Precision assessed as a percentage of the relative standard deviation %RSD was found to be 17.4, 7.1, and 7.8% for 10, 70, and 180 mu g L-1 levels, respectively. The method showed satisfactory results even in the presence of other ions (Al3+, Cr3+, Co2+, Cu2+, Fe3+, Mn2+, Ba2+, Mg2+, and Li+). The performance of the new system was also evaluated for Cd2+ ions, as well as by using other magnetic particles available in our lab: magnetic carbon nanotubes (M-CNTs), magnetic restricted access carbon nanotubes (M-RACNT), magnetic poly (methacrylic acid-co-ethylene glycol dimetha-crylate) (M-PMA), magnetic nanoparticles coated with orange powder peel (M-OPP) , magnetic nanoparticles covered with SiO2 (M -SiO2). Analytical signals increased for both analytes in all sorbents (increases of about 4-37 times), attesting the high potential , applicability of the proposed method. Simplicity, high analytical frequency, high detectability and reproducibility, low cost, and possibility of being totally mechanized are the most relevant advantages. (AU)

Processo FAPESP: 14/50867-3 - INCT 2014: Instituto Nacional de Ciência e Tecnologia de Bioanalítica
Beneficiário:Marco Aurelio Zezzi Arruda
Modalidade de apoio: Auxílio à Pesquisa - Temático