Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Aurora-A high-resolution powder diffractometer installed on the IEA-R1 research reactor at IPEN-CNEN/SP

Texto completo
Autor(es):
Parente, C. B. R. [1] ; Mazzocchi, V. L. [1] ; Mestnik-Filho, J. [1] ; Mascarenhas, Y. P. [2] ; Berliner, R. [3]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] IPEN CNEN SP, BR-05422970 Sao Paulo - Brazil
[2] USP, Inst Fis Sao Carlos, BR-13560940 Sao Carlos, SP - Brazil
[3] Instrumentat Associates, Durham, NC 27709 - USA
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SP; v. 622, n. 3, p. 678-684, OCT 21 2010.
Citações Web of Science: 3
Resumo

A high-resolution powder diffractometer (HRPD) was installed on the IEA-R1 research reactor at IPEN-CNEN/SP, Sao Paulo, SP, Brazil. It is an extensive upgrade of the old IPEN-CNEN/SP multipurpose neutron diffractometer which used a single boron trifluoride (BF(3)) detector and a flat mosaic single crystal copper monochromator. The main modifications introduced were the installation of a position sensitive detector (PSD) and a focusing silicon monochromator. Placed at a distance of 1600 mm from sample, the PSD spans an angular range of 20 degrees of a diffraction pattern. An extensive powder diffraction pattern can be obtained by collecting data in contiguous 20 degrees segments. The double-focusing perfect single crystal silicon monochromator, installed in a take-off angle of 84 degrees, can be positioned to produce 4 different wavelengths, namely 1.111, 1.399, 1.667 and 2.191 angstrom (nominal values). Diffraction patterns, obtained with the instrument, have shown a quite good resolution. Curves full width at half maximum (FWHM) vs. scattering angle (2 theta) have been measured with powdered alumina using three vanadium sample holders 1/8, 1/4 and 3/8 in. in diameter. Such curves give the resolution that can be expected from the instrument in an interval 2 theta from 5 degrees to 130 degrees. In comparison to the former instrument, the new diffractometer has much better resolution and is, per intensity point, ca. 600 times faster in data acquisition. (C) 2010 Elsevier B.V. All rights reserved. (AU)

Processo FAPESP: 95/05173-0 - Aperfeiçoamento das condições de difratometria de nêutrons no IPEN
Beneficiário:Carlos Benedicto Ramos Parente
Modalidade de apoio: Auxílio à Pesquisa - Programa Infraestrutura - Equipamentos