Does Adhesive Thickness Affect Resin-dentin Bond Strength After Thermal/Load Cycling?

Texto completo
Autor(es):
Lodovici, E. [1] ; Reis, A. [2] ; Geraldeli, S. [3, 4] ; Ferracane, J. L. [5] ; Ballester, R. Y. [1] ; Filho, L. E. R. [1]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Sch Dent, Dept Biomat & Oral Biochem, Sao Paulo - Brazil
[2] Univ Estadual Ponta Grossa, Dept Restorat Dent, Ponta Grossa, Parana - Brazil
[3] Univ Iowa, Dows Inst Dent Res, Iowa City, IA - USA
[4] Univ Iowa, Dept Operat Dent, Iowa City, IA - USA
[5] Oregon Hlth & Sci Univ, Sch Dent, Dept Restorat Dent, Portland, OR 97201 - USA
Número total de Afiliações: 5
Tipo de documento: Artigo Científico
Fonte: Operative Dentistry; v. 34, n. 1, p. 58-64, JAN-FEB 2009.
Citações Web of Science: 21
Resumo

This study evaluated the influence of adhesive layer thickness (ADL) on the resin-dentin bond strength of two adhesive systems (AS) after ther-mal and mechanical loading (TML). A flat superficial dentin surface was exposed with 600-grit SiC paper on 40 molars. After primer application, the adhesive layer of Scotchbond Multipurpose (SBMP) or Clearfil SE Bond (CSEB) was applied in one or two layers to a delimited area (52 mm(2)) and resin blocks (Filtek 2250) were built incrementally: Half of the sample was stored in distilled water (37 C, 24 hours) and submitted to thermal (1,000; 5 degrees-55 degrees C) and mechanical cycles (500,000; 10kgf) {[}TML]. The other half was stored in distilled water (72 hours). The teeth were then sectioned to obtain sticks (0.8 mm(2)) to be tested under tensile mode (1.0 mm/minute). The fracture mode was analyzed at 400x. The BS from all sticks from the same tooth was averaged for statistical purposes. The data was analyzed by three-way ANOVA. The x(2) test was used (p<0.05) to compare the frequency of pre-testing failure specimens. Higher BS values were observed for SBMP regardless of the ADL. The TML reduced the BS values irrespective of the adhesive employed and the ADL. A higher frequency of pre-testing failure specimens was observed for the cycled groups. A thicker adhesive layer, acting as an intermediate flexible layer, did not min-imize the damage caused by thermal/mechanical load cycling for a three-step etch-and-rinse and two-step self-etch system. (AU)