Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do SciELO, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Preload loss and bacterial penetration on different implant-abutment connection systems

Texto completo
Autor(es):
Antônio Pedro Ricomini Filho [1] ; Frederico Silva de Freitas Fernandes [2] ; Fabiana Gouveia Straioto [3] ; Wander José da Silva [4] ; Altair Antoninha Del Bel Cury [5]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] State University of Campinas. Piracicaba Dental School. Department of Prosthodontics and Periodontology - Brasil
[2] State University of Campinas. Piracicaba Dental School. Department of Prosthodontics and Periodontology - Brasil
[3] State University of Campinas. Piracicaba Dental School. Department of Prosthodontics and Periodontology - Brasil
[4] State University of Campinas. Piracicaba Dental School. Department of Prosthodontics and Periodontology - Brasil
[5] State University of Campinas. Piracicaba Dental School. Department of Prosthodontics and Periodontology - Brasil
Número total de Afiliações: 5
Tipo de documento: Artigo Científico
Fonte: Brazilian Dental Journal; v. 21, n. 2, p. 123-129, 2010-00-00.
Resumo

Preload loss can favor the occurrence of implant-abutment interface misfit, and bacterial colonization at this interface may lead to implant failure. The aim of this study was to evaluate the preload loss and bacterial penetration through the implant-abutment interface of conical and external hexagon connection systems subjected to thermal cycling and mechanical fatigue (TM). Four different implant-abutment connection systems were evaluated (n=6): external hexagon with universal post, Morse taper with universal post, Morse taper with universal post through bolt, and locking taper with standard abutment. The assemblies (implant-abutment) were subjected to a thermal cycling regimen (1,000 cycles of 5°C and 55°C) and to mechanical fatigue (1.0 million cycles, 1.0 Hz, 120 N). The assemblies were immersed in Tryptic Soy + Yeast Extract broth containing Streptococcus sanguinis and incubated at 37°C and 10% CO2 for 72 h. Detorque values were recorded. The bacterial penetration was assessed and the abutments were observed by scanning electron microscopy. The preload data were analyzed statistically by two-way ANOVA and Tukey’s test at 5% significance level. All screw abutment systems showed significantly higher (p<0.05) detorque values when subjected to TM and all conical systems presented bacterial penetration. The results show no relationship between the preload loss and the bacterial penetration. (AU)

Processo FAPESP: 06/05552-8 - Avaliação da infiltração bacteriana em diferentes tipos de junção pilar/implante
Beneficiário:Antônio Pedro Ricomini Filho
Modalidade de apoio: Bolsas no Brasil - Mestrado