Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Concentrations of metronidazole in human plasma and saliva after tablet or gel administration

Texto completo
Autor(es):
Bergamaschi, Cristiane de C. [1] ; Berto, Luciana A. [2] ; Venancio, Paulo C. [2] ; Cogo, Karina [2, 3] ; Franz-Montan, Michelle [2] ; Motta, Rogerio H. L. [4] ; Santamaria, Mauro P. [5] ; Groppo, Francisco C. [2]
Número total de Autores: 8
Afiliação do(s) autor(es):
[1] Univ Sorocaba, Sch Pharm, Dept Pharmaceut Sci, Sorocaba - Brazil
[2] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Pharmacol Anesthesiol & Therapeut, Piracicaba - Brazil
[3] Univ Santo Amaro, Dept Implantol, Sao Paulo - Brazil
[4] Sao Leopoldo Mand Dent Sch, Dept Pharmacol Anesthesiol & Therapeut, Campinas, SP - Brazil
[5] State Univ Sao Paulo, Dept Periodontol, Coll Dent, FOSJC, Sao Jose Dos Campos - Brazil
Número total de Afiliações: 5
Tipo de documento: Artigo Científico
Fonte: Journal of Pharmacy and Pharmacology; v. 66, n. 1, p. 40-47, JAN 2014.
Citações Web of Science: 6
Resumo

ObjectivesThe aim of this study was to determine the pharmacokinetic profile of metronidazole (Mtz) tablet and to compare Mtz gel and tablet concentrations in both blood plasma and saliva. MethodsIn this randomized cross-over study with a 1-week washout period, 13 volunteers randomly received one (a single oral dose of 750mg Mtz (Flagyl (R) - tablet) and 2) 3g of 15% Mtz benzoate gel (applied by using a dental tray). The HPLC with ultraviolet detection was used to quantify plasma and saliva concentrations of Mtz. The pharmacokinetic parameters (PPs) areas under the curves from 0 to 48h (AUC(0-48)) and from 0 to infinity (AUC(0-)), the maximum plasma concentration (C-max), the time to C-max, volume of distribution and renal clearance were determined for Mtz tablet. Key findingsConsidering the Mtz tablet, plasma showed higher Mtz concentration from 6 to 24h after drug administration and the highest values concerning AUC(0-48h) and AUC(0-) than those obtained in saliva (P<0.05). No significant differences were observed between plasma and saliva concentrations for Mtz gel. ConclusionsThe study showed that some PPs were higher in plasma (P<0.05) than in saliva concerning Mtz tablet. Gel formulation had similar Mtz bioavailability in plasma and saliva resulting in systemic absorption. (AU)

Processo FAPESP: 06/01492-0 - Avaliacao clinica e microbiologica do metronidazol em formulacao gel. perspectivas do uso em periodontia.
Beneficiário:Francisco Carlos Groppo
Modalidade de apoio: Auxílio à Pesquisa - Regular