Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Effects of cold fronts on MODIS-derived sensible and latent heat fluxes in Itumbiara reservoir (Central Brazil)

Texto completo
Autor(es):
Curtarelli, Marcelo [1] ; Alcantara, Enner [2] ; Renno, Camilo [1] ; Stech, Jose [1]
Número total de Autores: 4
Afiliação do(s) autor(es):
[1] Natl Inst Space Res, Sao Jose Dos Campos, SP - Brazil
[2] Sao Paulo State Univ, Dept Cartog, Presidente Prudente, SP - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: Advances in Space Research; v. 52, n. 9, p. 1668-1677, NOV 1 2013.
Citações Web of Science: 5
Resumo

In this work we investigate the cold front passage effects on sensible and latent heat flux in a tropical hydroelectric reservoir. The study area, Itumbiara reservoir (Goias State/Brazil) at the beginning of the austral winter, is characterized by the presence of a weak thermal stratification and the passage of several cold fronts from higher latitudes of South America. Sensible and latent heat fluxes were estimated considering the atmospheric boundary layer stability. In situ and MODIS water surface temperature data were used to adjust the coefficients for momentum and heat exchanges between water and atmosphere and spatialize the sensible and latent heat fluxes. The results showed that during a cold front event the sensible heat flux can be up to five times greater than the flux observed before. The latent heat flux tends to decrease during the cold front but increase again after the passage. The highest values of heat loss were observed at littoral zone and some Reservoir's embayment. The heat loss intensification can be separated in two moments: first, during the cold front passage, when the wind speed increases and the air temperature decreases; second, after the cold front passage, with air humidity decreasing. This can be considered a key process to understanding the heat loss in the Itumbiara reservoir. (C) 2013 COSPAR. Published by Elsevier Ltd. All rights reserved. (AU)

Processo FAPESP: 07/08103-2 - Estudo da circulação, qualidade da água e uso/ocupação do solo na bacia hidrográfica do Reservatório de Itumbiara
Beneficiário:José Luiz Stech
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 10/15075-8 - Estudo Numérico da Circulação e das Características Termodinâmicas da Água do Reservatório de Itumbiara
Beneficiário:Enner Herenio de Alcântara
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado
Processo FAPESP: 08/57719-9 - Programa de Mudanças Climáticas - INCT CLIMA
Beneficiário:Carlos Afonso Nobre
Modalidade de apoio: Auxílio à Pesquisa - Programa de Pesquisa sobre Mudanças Climáticas Globais - Temático