Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Wear resistance of a pressable low-fusing ceramic opposed by dental alloys

Texto completo
Autor(es):
Lapria Faria, Adriana Claudia [1] ; de Oliveira, Andre Almeida [1] ; Gomes, Erica Alves [1] ; Silveira Rodrigues, Renata Cristina [1] ; Ribeiro, Ricardo Faria [1]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Dept Dent Mat & Prosthodont, Dent Sch Ribeirao Preto, BR-14040904 Sao Paulo - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS; v. 32, p. 46-51, APR 2014.
Citações Web of Science: 7
Resumo

Dental alloys have increasingly replaced by dental ceramics in dentistry because of aesthetics. As both dental alloys and ceramics can be present in the oral cavity, the evaluation of the wear resistance of ceramics opposed by dental alloys is important. The aim of the present study was to evaluate wear resistance of a pressable low-fusing ceramic opposed by dental alloys as well as the microhardness of the alloys and the possible correlation of wear and antagonist microhardness. Fifteen stylus tips samples of pressable low-fusing ceramic were obtained, polished and glazed. Samples were divided into three groups according to the disk of alloy/metal to be used as antagonist: Nickel-Chromium (Ni-Cr), Cobalt-Chromium (Co-Cr) and commercially pure titanium (cp Ti). Vickers microhardness of antagonist disks was evaluated before wear tests. Then, antagonist disks were sandblasted until surface roughness was adjusted to 0.75 mu m. Wear tests were performed at a speed of 60 cycles/min and distance of 10 mm, in a total of 300,000 cycles. Before and after wear tests, samples were weighted and had their profile designed in an optical comparator to evaluate weight and height loss, respectively. Ni-Cr and cp Ti caused greater wear than Co-Cr, presenting greater weight (p=.009) and height (p=.002) loss. Cp Ti microhardness was lower than Ni-Cr and Co-Cr (p<.05). There is a positive correlation between weight and height loss (p<.05), but weight (p=.204) and height (p=.05) loss are not correlated to microhardness. The results suggest that pressable low-fusing ceramic presents different wear according to the dental alloy used as antagonist and the wear is not affected by antagonist microhardness. (c) 2013 Elsevier Ltd. All rights reserved. (AU)

Processo FAPESP: 11/21778-4 - Resistência ao desgaste de uma cerâmica prensada de baixa fusão frente às ligas odontológicas convencionais e ao Ti CP
Beneficiário:André Almeida de Oliveira
Modalidade de apoio: Bolsas no Brasil - Iniciação Científica