Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

High-throughput sugarcane leaf analysis using a low cost closed-vessel conductively heated digestion system and inductively coupled plasma optical emission spectroscopy

Texto completo
Autor(es):
Miranda, Kelber [1] ; Vieira, Alan Lima [1] ; Gomes Neto, Jose Anchieta [1]
Número total de Autores: 3
Afiliação do(s) autor(es):
[1] Sao Paulo State Univ, Dept Analyt Chem, BR-14801970 Araraquara, SP - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: ANALYTICAL METHODS; v. 6, n. 23, p. 9503-9508, 2014.
Citações Web of Science: 4
Resumo

Most small to medium-size laboratories involved in foliar diagnosis make use of digestion blocks with borosilicate glass tubes to decompose leaf samples. Then, the elements of interest can be simultaneously determined by ICP OES, except boron, because blank signals for this element are greater than the analytical signals. To determine boron by ICP OES, all samples are digested again using a dry ashing procedure, sometimes requiring up to 24 h per a small group of samples. In order to provide a low-cost alternative to prepare leaf samples for elemental determination, including boron, quartz digestion tubes were developed for the recently proposed closed-vessel conductively heated digestion system (CHDS). The performance of the CHDS with quartz tubes was evaluated by converting sugarcane leaf samples into solutions for subsequent determinations of macro- (Ca, K, Mg, P, and S) and micronutrients (Al, B, Cu, Fe, Mn and Zn) by ICP OES. The analytical procedure was validated with three certified reference materials and applied to ten sugarcane leaf samples. The results obtained for Al, B, Ca, Cu, Fe, K, Mg, Mn, P, S and Zn determined by ICP OES and the conductively heated digestion system with quartz tubes were in fair agreement with those obtained after closed-vessel microwave-assisted digestion. For all elements determined, the relative standard deviation (n = 3) was usually below 5%. The use of quartz digestion tubes resulted in lower blank values for boron, allowing the determination of all elements of interest in one run. (AU)

Processo FAPESP: 12/02891-7 - Construção e avaliação de um sistema miniaturizado de digestão em frasco fechado para preparar materiais botânicos para análise elementar
Beneficiário:Kelber dos Anjos de Miranda
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado