Comparison of Different Methods of Erythrocyte Dysmorphism Analysis to Determine the Origin of Hematuria

Texto completo
Autor(es):
Martinez, Marila Gaste [1] ; Silva, Vanessa dos S. [1] ; do Valle, Adriana P. [2] ; Amaro, Carmen R. P. R. [1] ; Corrente, Jose E. [3] ; Martin, Luis Cuadrado [1]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Univ Estadual Paulista, Botucatu Med Sch, Div Nephrol, Botucatu, SP - Brazil
[2] Univ Estadual Paulista, Botucatu Med Sch, Dept Internal Med, Div Clin Pathol, Botucatu, SP - Brazil
[3] Univ Estadual Paulista, Botucatu Med Sch, Dept Biostat, Botucatu, SP - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: NEPHRON CLINICAL PRACTICE; v. 128, n. 1-2, p. 88-94, DEC 2014.
Citações Web of Science: 0
Resumo

Background/Aims: There is disagreement regarding the performance of conventional optical microscopy to assess the origin of hematuria. The aim of this study was to determine the optimal cutoff point for dysmorphic cells in order to detect glomerular hematuria by optical and phase-contrast microscopy. Methods: In total, 131 urine samples (66 from patients with glomerulopathies and 65 from nephrolithiasis patients) were evaluated in a blinded fashion. The percentages of doughnut cells and acanthocytes were verified by optical and phase-contrast microscopy. A total of 131 patients were randomly allocated to the derivation (n = 73) and validation (n = 58) groups. Receiver-operating characteristic (ROC) curves were plotted to check the discriminatory power of each group and the best cutoff points were determined by the Youden index in the derivation group and subsequently tested in the validation group. Results: All areas under the ROC curve (AUCs) were statistically significant using both methods (conventional optical and phasecontrast microscopy) and both groups (derivation and validation). AUCs did not differ between different glomerulopathies. The best cutoff point to determine the glomerular origin of hematuria by total dysmorphic cells was 22% using an optical conventional microscope and 40% by phase-contrast microscopy. Conclusion: We determined the best cutoff points to interpret erythrocyte dysmorphism and demonstrated that it is possible to discriminate the origin of hematuria by evaluating erythrocyte dysmorphism in urinalysis using either an optical or a phase-contrast microscope. (C) 2014 S. Karger AG, Basel (AU)

Processo FAPESP: 10/14686-3 - Verificação do melhor ponto de corte da porcentagem de dismorfismo eritrocitário avaliado por diferentes métodos associados ou não à dosagem de macroalbuminúria e microalbuminúria no diagnóstico da origem da hematúria
Beneficiário:Marila Gaste Martinez
Modalidade de apoio: Bolsas no Brasil - Mestrado
Processo FAPESP: 10/11591-1 - Verificação do melhor ponto de corte da porcentagem de dismorfismo eritrocitário avaliado por diferentes métodos associados ou não à dosagem de proteinúria e microalbuminúria no diagnóstico da origem da hematúria.
Beneficiário:Luis Cuadrado Martin
Modalidade de apoio: Auxílio à Pesquisa - Regular