Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Phosphorus quantification in fertilizers using laser induced breakdown spectroscopy (LIBS): a methodology of analysis to correct physical matrix effects

Texto completo
Autor(es):
Mostrar menos -
Marangoni, Bruno S. [1] ; Silva, Kleydson S. G. [2] ; Nicolodelli, Gustavo [2] ; Senesi, Giorgio S. [3] ; Cabral, Jader S. [4] ; Villas-Boas, Paulino R. [2] ; Silva, Caroline S. [5] ; Teixeira, P. C. [6] ; Nogueira, Ana Rita A. [5] ; Benites, Vinicius M. [6] ; Milori, Debora M. B. P. [2]
Número total de Autores: 11
Afiliação do(s) autor(es):
[1] Univ Fed Sao Carlos, Dept Fis, BR-13565905 Sao Carlos, SP - Brazil
[2] Embrapa Instrumentacao, BR-13560970 Sao Carlos, SP - Brazil
[3] CNR, Inst Inorgan Methodol & Plasmas, I-70126 Bari - Italy
[4] Univ Fed Uberlandia, Inst Fis, BR-38400902 Uberlandia, MG - Brazil
[5] Embrapa Pecuaria Sudeste, BR-13560970 Sao Carlos, SP - Brazil
[6] Embrapa Solos, BR-22460000 Rio De Janeiro, RJ - Brazil
Número total de Afiliações: 6
Tipo de documento: Artigo Científico
Fonte: ANALYTICAL METHODS; v. 8, n. 1, p. 78-82, 2016.
Citações Web of Science: 26
Resumo

The aim of this study was to develop a quantitative method to determine phosphorus in fertilizers of different matrix compositions using the laser induced breakdown spectroscopy (LIBS) technique. The LIBS spectra were acquired on 26 samples of organic and inorganic fertilizers by using a low cost, portable, gated CCD system in the atmospheric environment. Inductively coupled plasma optical emission spectroscopy (ICP-OES) was used as the reference technique. A method was developed to remove the outlier spectra and perform the baseline correction and peak normalization. By applying the proposed corrections, the linear correlation between LIBS and ICP increased from R = 0.76 to R = 0.95. An average error of 15% found in cross-validation of LIBS quantification appeared feasible for P quantification in fertilizers. Two reference samples with different matrix compositions were also analyzed, and the absolute error in the quantification was below 5%. Further, no significant fluctuation was found in P quantification when LIBS was performed over 150 days. (AU)

Processo FAPESP: 13/02165-7 - Desenvolvimento de novo método para quantificação de nutrientes e contaminantes em fertilizantes: novo uso da ferramenta libs
Beneficiário:Bruno Spolon Marangoni
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado