Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

The effect of casting and masticatory simulation on strain and misfit of implant-supported metal frameworks

Texto completo
Autor(es):
Brilhante Bhering, Claudia Lopes [1] ; Vieira Marques, Isabella da Silva [1] ; Ferreira Koyama Takahashi, Jessica Mie [2] ; Ricardo Barao, Valentim Adelino [1, 3] ; Xediek Consani, Rafael Leonardo [1] ; Mesquita, Marcelo Ferraz [1]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Prosthodont & Periodontol, Sao Paulo - Brazil
[2] Amazonas State Univ, Hlth Sci Grad Sch, Dept Prosthodont, Manaus, Amazonas - Brazil
[3] Ave Limeira 901, BR-13414903 Sao Paulo - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: Materials Science & Engineering C-Materials for Biological Applications; v. 62, p. 746-751, MAY 1 2016.
Citações Web of Science: 6
Resumo

The influence of casting and masticatory simulation on marginal misfit and strain in multiple implant-supported prostheses was evaluated. Three-unit screw retained fixed dental prosthesis (FDP) and screw retained full-arch fixed dental prosthesis (FAFDP) frameworks were made using calcinable or overcasted cylinders on conical dental implant abutment. Four groups were obtained according to the cylinder and prosthesis type (n = 10). Frameworks were casted in CoCr alloy and subjected to strain gauge analyses and marginal misfit measurements before and after 10(6) mechanical cycles (2 Hz/280 N). Results were submitted to ANOVA, Tukey's HSD and Pearson correlation test (alpha = 0.05). No difference was found on misfit among all groups and times (p > 0.05). Overcasted frameworks showed higher strain than the calcinable ones (FDP Initial p = 0.0047; Final p = 0.0004; FAFDP Initial p = 0.0476; Final p = 0.0115). The masticatory simulation did not influence strain (p > 0.05). No correlation was observed between strain and misfit (r = 0.24; p > 0.05). In conclusion, the marginal misfit value in the overcasted full-arch frameworks was higher than clinical acceptable data. It proved that overcasted method is not an ideal method for full-arch prosthesis. Overcasted frameworks generate higher strain upon the system. The masticatory simulation had no influence on misfit and strain of multiple prostheses. (C) 2016 Elsevier B.V. All rights reserved. (AU)

Processo FAPESP: 11/03032-5 - Avaliação da biomecânica de reabilitações múltiplas implantossuportadas: estudo comparativo de técnicas de fundição e métodos de análise de tensão
Beneficiário:Marcelo Ferraz Mesquita
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 11/02841-7 - Efeito da ciclagem mecânica e da técnica de fundição das infraestruturas sobre o desajuste marginal, tensão, e torque de afrouxamento em próteses múltiplas implantossuportadas
Beneficiário:Cláudia Lopes Brilhante Bhering
Modalidade de apoio: Bolsas no Brasil - Mestrado