Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Effects of artificial aging conditions on yttria-stabilized zirconia implant abutments

Texto completo
Autor(es):
Basilio, Mariana de Almeida ; Cardoso, Katia Vieira ; Antonio, Selma Gutierrez ; Rizkalla, Amin Sami ; Santos Junior, Gildo Coelho ; Arioli Filho, Joao Neudenir
Número total de Autores: 6
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF PROSTHETIC DENTISTRY; v. 116, n. 2, p. 277-285, AUG 2016.
Citações Web of Science: 11
Resumo

Statement of problem. Most ceramic abutments are fabricated from yttria-stabilized tetragonal zirconia (Y-TZP). However, Y-TZP undergoes hydrothermal degradation, a process that is not well understood. Purpose. The purpose of this in vitro study was to assess the effects of artificial aging conditions on the fracture load, phase stability, and surface microstructure of a Y-TZP abutment. Material and methods. Thirty-two prefabricated Y-TZP abutments were screwed and tightened down to external hexagon implants and divided into 4 groups (n = 8): C, control; MC, mechanical cycling (1x10(6) cycles; 10 Hz); AUT, autoclaving (134 degrees C; 5 hours; 0.2 MPa); and TC, thermal cycling (10(4) cycles; 5 degrees/55 degrees C). A single-load-to-fracture test was performed at a crosshead speed of 0.5 mm/min to assess the assembly's resistance to fracture (ISO Norm 14801). X-ray diffraction (XRD) analysis was applied to observe and quantify the tetragonal-monoclinic (t-m) phase transformation. Representative abutments were examined with high-resolution scanning electron microscopy (SEM) to observe the surface characteristics of the abutments. Load-to-fracture test results (N) were compared by ANOVA and Tukey test (alpha=.05). Results. XRD measurements revealed the monoclinic phase in some abutments after each aging condition. All the aging conditions reduced the fracture load significantly (P<.001). Mechanical cycling reduced the fracture load more than autoclaving (P=.034). No differences were found in the process of surface degradation among the groups; however, the SEM detected grinding-induced surface flaws and microcracks. Conclusions. The resistance to fracture and the phase stability of Y-TZP implant abutments were susceptible to hydrothermal and mechanical conditions. The surface microstructure of Y-TZP abutments did not change after aging conditions. (AU)

Processo FAPESP: 10/06651-5 - Análise comparativa da estabilidade da união parafusada em abutments de zircônia sobre implantes após carga cíclica
Beneficiário:João Neudenir Arioli Filho
Modalidade de apoio: Auxílio à Pesquisa - Regular