Multi-energy calibration applied to atomic spectrometry

Texto completo
Autor(es):
Virgilio, Alex ; Goncalves, Daniel A. ; McSweeney, Tina ; Gomes Neto, Jose A. ; Nobrega, Joaquim A. ; Donati, George L.
Número total de Autores: 6
Tipo de documento: Artigo Científico
Fonte: Analytica Chimica Acta; v. 982, p. 31-36, AUG 22 2017.
Citações Web of Science: 29
Resumo

Multi-energy calibration (MEC) is a novel strategy that explores the capacity of several analytes of generating analytical signals at many different wavelengths (transition energies). Contrasting with traditional methods, which employ a fixed transition energy and different analyte concentrations to build a calibration plot, MEC uses a fixed analyte concentration and multiple transition energies for calibration. Only two calibration solutions are required in combination with the MEC method. Solution 1 is composed of 50% v v(-1) sample and 50% v v(-1) of a standard solution containing the analytes. Solution 2 has 50% v v(-1) sample and 50% v v(-1) blank. Calibration is performed by running each solution separately and monitoring the instrument response at several wavelengths for each analyte. Analytical signals from solutions 1 and 2 are plotted on the x-axis and y-axis, respectively, and the analyte concentration in the sample is calculated from the slope of the resulting calibration curve. The method has been applied to three different atomic spectrometric techniques (ICP OES, MIP OES and HR-CS FAAS). Six analytes were determined in complex samples (e.g. green tea, cola soft drink, cough medicine, soy sauce, and red wine), and the results were comparable with, and in several cases more accurate than, values obtained using the traditional external calibration, internal standardization, and standard additions methods. MEC is a simple, fast and efficient matrix-matching calibration method. It may be applied to any technique capable of simultaneous or fast sequential monitoring of multiple analytical signals. (C) 2017 Elsevier B.V. All rights reserved. (AU)

Processo FAPESP: 14/18393-1 - Avaliação da análise em fluxo por gradiente como estratégia de calibração para técnicas espectroanalíticas com fonte de plasma
Beneficiário:Alex Virgilio
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado