Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Development of Analytical Procedures for Lead Determination in Incense by Graphite Furnace AAS

Texto completo
Autor(es):
Coco, Jessica [1] ; Bechlin, Marcos A. [1] ; Barros, Ariane I. [1] ; Ferreira, Edilene C. [1] ; Veiga, Marcia A. M. S. [2] ; Neto, Jose A. Gomes [1]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Sao Paulo State Univ, Inst Chem, BR-14800060 Araraquara, SP - Brazil
[2] Univ Sao Paulo, FFCLRP, Dept Quim, Ribeirao Preto, SP - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: ATOMIC SPECTROSCOPY; v. 38, n. 6, p. 208-212, NOV-DEC 2017.
Citações Web of Science: 3
Resumo

The use of incense has increased over the past years; however, few studies have been carried out concerning the quantification of toxic elements. This article describes the development of analytical methods for Pb determination in the rod and coating of incense sticks by solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry (SS HR-CS GFAAS). For comparative purposes, samples were also analyzed by line source graphite furnace atomic absorption spectrometry (IS GFAAS) after acid microwave-assisted digestion. The concentration of lead varied from 0.06 a 2.17 mu g g(-1) in the rods and 1.06 to 6.60 mu g g(-1) for the coating. A paired t-test at a 95% confidence level showed that the SS HR-CS GFAAS results were in agreement with those obtained by LS GFAAS. The precision of measurements obtained by SS HR-CS GFAAS varied from 0.5 to 16% and 1.9 to 15% for rod and coating, respectively. Also, emission of lead generated when the incense stick samples were burning was evaluated by ash analysis and the mass balance applied for total lead in the whole samples and the remaining lead in the ashes. These findings showed that 25 to 80% of the total lead content in incense may be released to the air. These large variations may be related to the type of raw materials (chemical composition) employed in incense production. (AU)

Processo FAPESP: 14/12595-1 - Avaliação da amostragem direta de sólidos aliada a espectrometria de absorção atômica com fonte contínua e de alta resolução em análises químicas de amostras de difícil solubilização
Beneficiário:José Anchieta Gomes Neto
Modalidade de apoio: Auxílio à Pesquisa - Regular