Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Torsional fatigue resistance of pathfinding instruments manufactured from several nickel-titanium alloys

Texto completo
Autor(es):
Alcalde, M. P. [1] ; Duarte, M. A. H. [1] ; Bramante, C. M. [1] ; Tanomaru-filho, M. [2] ; Vasconcelos, B. C. [3] ; So, M. V. R. [4] ; Vivan, R. R. [1]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Bauru Dent Sch, Dept Dent Endodont & Dent Mat, Bauru, SP - Brazil
[2] Sao Paulo State Univ, Araraquara Dent Sch, Dept Restorat Dent, Araraquara, SP - Brazil
[3] Univ Fed Ceara, Sch Dent Sobral, Sobral, CE - Brazil
[4] Univ Fed Rio Grande do Sul, Dept Endodont, Porto Alegre, RS - Brazil
Número total de Afiliações: 4
Tipo de documento: Artigo Científico
Fonte: International Endodontic Journal; v. 51, n. 6, p. 697-704, JUN 2018.
Citações Web of Science: 1
Resumo

AimTo evaluate the torsional properties of pathfinding nickel-titanium (NiTi) rotary instruments manufactured from several NiTi alloys, ProGlider (M-wire), Hyflex GPF (conventional NiTi Wire and controlled memory wire), Logic (conventional NiTi wire and controlled memory wire) and Mtwo (conventional NiTi wire). MethodologyA total of 56 NiTi instruments from Glidepath rotary systems (n=8) were used: Logic (size 25, .01 taper), Logic CM (size 25, .01 taper), ProGlider (size 16, .02 taper), Hyflex GPF (size 15, .01 taper), Hyflex GPF CM (size 15, .02 taper; size 20, .02 taper) and Mtwo (size 10, .04 taper). The torsion tests were performed based on ISO 3630-1 (1992). Three millimetres of each instrument tip was clamped to a small load cell by a lever arm linked to the torsion axis. Data were analysed using a one-way analysis of variance (anova) and Tukey test with a significance level at a=5%. ResultsThe Logic size 25, .01 taper had significantly higher torsional strength values (P<0.05). The ProGlider was significantly different when compared with Hyflex GPF size 15, .01 taper and size 15, .02 taper (P<0.05). The Logic CM size 25, .01 taper had significantly higher torsional strength than Hyflex GPF size 15, .01 taper and size 15, .02 taper (P<0.05). No difference was found amongst Mtwo size 10, .04 taper and Hyflex GPF groups (size 15, .01 taper; size 15, .02 taper; size 20, .02 taper). In relation to the angle of rotation, Logic CM size 25, .01 taper and Hyflex GPF size 15, .01 taper had the highest angle values (P<0.05). The ProGlider had the lowest angle values in comparison with all the groups (P<0.05) followed by Mtwo size 10, .04 taper. The Logic size 25, .01 taper had significantly higher angle of rotation values than ProGlider and Mtwo size 10, .04 taper (P<0.05). ConclusionThe Logic size 25, .01 taper instrument made of conventional NiTi alloy had the highest torsional strength of all instruments tested. In addition, the ProGlider instrument manufactured from M-Wire alloy had the lowest angle of rotation to fracture in comparison with the other instruments. (AU)

Processo FAPESP: 14/25520-0 - Avaliação das propriedades químicas, resistência torcional e flexural, caracterização geométrica e superficial de instrumentos endodônticos em função do tratamento da liga: análise após 3 vezes simulando uso clínico
Beneficiário:Rodrigo Ricci Vivan
Modalidade de apoio: Auxílio à Pesquisa - Regular