Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Complexing porous polymer monoliths for online solid-phase extraction of metals in sequential injection analysis with electrochemical detection

Texto completo
Autor(es):
Ribeiro, Luiz Fernando [1] ; Masini, Jorge Cesar [1]
Número total de Autores: 2
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Inst Quim, Dept Quim Fundamental, Ave Prof Lineu Prestes 748, BR-05508000 Sao Paulo - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: Talanta; v. 185, p. 387-395, AUG 1 2018.
Citações Web of Science: 12
Resumo

A monolithic column affording complexing groups was synthesized for automated solid-phase extraction of potentially toxic metal ions in a low-pressure sequential injection analyzer. Poly(glycidyl methacrylate-co-ethylene dimethacrylate) monoliths were synthesized by free-radical polymerization in the coffins of fused silica lined stainless-steel tubes (2.10 mm i.d. x 5-6 cm length). High permeability (4.33 x 10(-13) m(2)) was achieved for monoliths polymerized for 24 h at 60 degrees C from a mixture of 30 wt% glycidyl methacrylate, 10 wt% ethylene glycol dimethacrylate, 35 wt% n-propanol, 20 wt% 1,4 butanediol and 5 wt% water. Azobisisobutyronitrile (1 wt % with respect to the monomers) initiated the free-radical polymerization. These generic columns were modified with iminodiacetate to create complexing functionalities on the polymer surface, being further used for online solid-phase extraction of Cu2+, Pb2+ and Cd2+ from natural, tap and drinking waters prior to their determination by stripping chronopotentiometry. The high permeability of the column allowed the loading, washing, eluting and reconditioning steps to be made at flow rate of 10 mu L s(-1). The limits of detection and quantification achieved by processing 1500 mu L of sample were 0.51 and 1.7 mu g L-1 for Cu2+, 1.4 and 4.7 mu g L-1 for Pb2+, and 1.2 and 3.8 mu g L-1 for Cd2+, respectively. Recoveries were between 75.5% and 117%, obtained by quantification via external calibration curves, thus eliminating the need for the laborious standard addition strategies. (AU)

Processo FAPESP: 13/18507-4 - Materiais monolíticos porosos para separações cromatográficas e preparo de amostras
Beneficiário:Jorge Cesar Masini
Modalidade de apoio: Auxílio à Pesquisa - Regular