Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Reproducibility of heart rate recovery in patients with intermittent claudication

Texto completo
Autor(es):
Fecchio, Rafael Yokoyama [1] ; Chehuen, Marcel [1] ; Pecanha, Tiago [1] ; Cucato, Gabriel Grizzo [1, 2] ; Riani Costa, Luiz Augusto [1] ; Leicht, Anthony Scott [3] ; Ritti-Dias, Raphael Mendes [2] ; Wolosker, Nelson [2] ; de Moraes Forjaz, Claudia Lucia [1]
Número total de Autores: 9
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Sch Phys Educ & Sport, Sao Paulo - Brazil
[2] Albert Einstein Israelite Hosp, Sao Paulo - Brazil
[3] James Cook Univ, Sport & Exercise Sci, Townsville, Qld - Australia
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING; v. 38, n. 4, p. 603-609, JUL 2018.
Citações Web of Science: 1
Resumo

BackgroundPostexercise heart rate recovery (HRR) is a non-invasive tool for cardiac autonomic function assessment. Reproducibility of HRR has been established in healthy subjects; however, no study has evaluated this reproducibility in clinical populations who may present autonomic dysfunction. Patients with peripheral artery disease and intermittent claudication (IC) often present altered cardiac autonomic function and HRR could be an interesting tool for evaluating autonomic responses to interventions in this population. Therefore, the reproducibility of HRR should be determined in this specific population. ObjectiveTo determine the reproducibility of HRR indices in patients with IC. MethodsNineteen men with IC underwent two repeated maximal treadmill tests. Raw HR and relative HRR (difference to exercise peak) indices measured at 30, 60, 120, 180, 240 and 300s of recovery were evaluated. The presence of systematic bias was assessed by comparing test and retest mean values via paired t-test. Reliability was assessed by intraclass correlation coefficient (ICC), and agreement by typical error (TE), coefficient of variation (CV) and minimal detectable difference (MDD). ResultsThere were no significant differences between the test and retest values of all raw HR and relative HRR indices (P0<bold></bold>05), except for HR120s (P=0<bold></bold>032). All indices exhibited excellent reliability (ICC0<bold></bold>78). Raw HR and relative HRR indices showed TEs6<bold></bold>4bpm and MDDs17<bold></bold>8bpm. In addition, all indices showed CVs13<bold></bold>2%, except HRR30s (CV=45<bold></bold>6%). ConclusionsThe current results demonstrated that most HRR indices were highly reproducible with no systematic error, excellent reliability and good agreement in patients with IC following maximal graded exercise. (AU)

Processo FAPESP: 15/13800-0 - Treinamento de caminhada na claudicação intermitente: respostas em repouso e após exercício máximo.
Beneficiário:Cláudia Lúcia de Moraes Forjaz
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 09/17371-6 - Respostas cardiovasculares agudas e crônicas ao exercício físico em indivíduos com claudicação intermitente
Beneficiário:Cláudia Lúcia de Moraes Forjaz
Modalidade de apoio: Auxílio à Pesquisa - Regular