Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Partial combination of composite strategy and the B3LYP functional for the calculation of enthalpies of formation

Texto completo
Autor(es):
Caldeira, Mariana Toretti [1] ; Custodio, Rogerio [1]
Número total de Autores: 2
Afiliação do(s) autor(es):
[1] Univ Estadual Campinas, Inst Quim, POB 6154, BR-13083970 Campinas, SP - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: Journal of Molecular Modeling; v. 25, n. 3 MAR 2019.
Citações Web of Science: 0
Resumo

The B3LYP functional was re-optimized using partially composite methods for the calculation of standard enthalpies of formation. Two initial methods (B3LYP-MCM1 and B3LYP-MCM2) differing in the type and number of optimized parameters were analyzed using B3LYP/6-31+G(2df,p) as the reference energy. For the first method (B3LYP-MCM1), the exchange-correlation and higher-level correction parameters (HLC) were optimized and for the second method (B3LYP-MCM2), in addition to the previous parameters, scaling of the basis functions responsible for large errors in the enthalpy of formation were also optimized. The best parameters were also used as adapted functionals generating two other methods referred to as: B3LYP-MF1 and B3LYP-MF2. The best-performing results (B3LYP-MCM2 and B3LYP-MF2) presented mean absolute errors near 2.3kcalmol(-1) for the G3/05 test set. This is a significant improvement when compared with the respective results from B3LYP/6-31+G(2df,p), which yielded a mean absolute error of 5.3kcalmol(-1). The errors were larger for B3LYP-MCM1 (4.17kcalmol(-1)) and B3LYP-MF1 (3.98kcalmol(-1)). The scaling of the experimental atomization energies used for the calculation of enthalpy of formation was also tested for all four methods. This empirical adjustment reduced the errors to 2kcalmol(-1). The uncertainty of the best results with 95% confidence tended to be +/- 5.5kcalmol(-1). Substantial improvements were associated with the basis set adjustments. (AU)

Processo FAPESP: 13/08293-7 - CECC - Centro de Engenharia e Ciências Computacionais
Beneficiário:Munir Salomao Skaf
Modalidade de apoio: Auxílio à Pesquisa - Centros de Pesquisa, Inovação e Difusão - CEPIDs
Processo FAPESP: 17/11485-6 - Desenvolvimentos computacionais e teóricos baseados em métodos ab initio e na Teoria do Funcional de Densidade
Beneficiário:Rogério Custodio