Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Matte photographic paper as a low-cost material for metal ion retention and elemental measurements with laser-induced breakdown spectroscopy

Texto completo
Autor(es):
Papai, Rodrigo [1, 2] ; Mariano, Cleide da Silva [1, 3] ; Pereira, Camila Vilela [1] ; Ferreira da Costa, Paulo Vinicius [1] ; Leme, Flavio de Oliveira [1] ; Nomura, Cassiana Seimi [4] ; Gaubeur, Ivanise [1]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] Univ Fed ABC, Ctr Ciencias Nat & Humans, Lab Espectroanalit Mol & Atom, Ave Estados 5001, Bloco L-407, BR-09210971 Santo Andre, SP - Brazil
[2] IPT, Ave Prof Almeida Prado 532, Predio 2, BR-05508901 Sao Paulo, SP - Brazil
[3] Fac Pentagono FAPEN, Rua Cel Fernando Prestes 326, BR-09020110 Santo Andre, SP - Brazil
[4] Univ Sao Paulo, Dept Quim Fundamental, Inst Quim, Ave Prof Lineu Presses 748, BR-05508000 Sao Paulo, SP - Brazil
Número total de Afiliações: 4
Tipo de documento: Artigo Científico
Fonte: Talanta; v. 205, DEC 1 2019.
Citações Web of Science: 0
Resumo

Matte photographic paper was explored as a low-cost material for metal-ion retention. The extraction was promoted by ultrasound, the mechanical waves of which forced adhesion to the photographic paper surface of an ion pair formed by DTAB (dodecyltrimethylammonium bromide) with the anionic coordination complex formed by metal ions and SPADNS (1,8-dihydroxy-2-(4-sulfophenylazo)naphthalene-3,6-disulfonic acid trisodium salt). As a proof of concept, the migration of copper ions present in aqueous solution to the solid phase and their direct measurement by laser-induced breakdown spectroscopy (LIBS) was evaluated. The main parameters that affected the extraction (paper type and sonication time) and analyte detection in the solid phase (delay, spot size and accumulated number of pulses) were optimised in a univariate way. The conditions influencing the complexation reaction and formation of the ion pair in aqueous solution (pH and copper, SPADNS and DTAB concentrations) were set according to a previous study. Under the optimised conditions, it was possible to use this extraction technology as an alternative in determining copper content in aqueous solutions by LIES, overcoming the intrinsic difficulties of this instrumental technique in the analysis of liquid samples. The calibration curves were obtained in a linear range of 0.50-7.50 mg L-1 copper in solution, with detection and quantification limits estimated at 0.08 and 0.24 mg L-1, respectively. The precision of the method was less than 4.3% and the accuracy was checked by spike and recovery tests on liquid samples with different chemical compositions and by comparison of LIBS results with graphite furnace atomic absorption spectrometry data. The potential of the proposed method for extraction of Al3+, Ag+, Fe3+, Mn2+, Ni2+ and Zn2+ was also evaluated and adequate extraction efficiencies were obtained. The proposed method stands out due to its low cost and ease of execution. (AU)

Processo FAPESP: 17/10346-2 - Desenvolvimento de método de análises quantitativas diretas de materiais silicosos: espectrometria de emissão óptica com plasma induzido por laser e fluorescência de raio-x por reflexão total
Beneficiário:Cassiana Seimi Nomura
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 16/23878-0 - Consolidação e inovação da linha de pesquisa: desenvolvimento de métodos analíticos combinados a microextração em fase líquida
Beneficiário:Ivanise Gaubeur
Modalidade de apoio: Auxílio à Pesquisa - Regular