Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do SciELO, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Influence of the growth pattern on cortical bone thickness and mini-implant stability

Texto completo
Autor(es):
Carolina Carmo de Menezes [1] ; Sérgio Estelita Barros [2] ; Diego Luiz Tonello [3] ; Aron Aliaga-Del Castillo [4] ; Daniela Garib [5] ; Silvio Augusto Bellini-Pereira [6] ; Guilherme Janson [7]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] Universidade de São Paulo. Faculdade de Odontologia de Bauru. Departamento de Ortodontia - Brasil
[2] Universidade Federal do Rio Grande do Sul. Faculdade de Odontologia. Departamento de Ortodontia - Brasil
[3] Universidade de São Paulo. Faculdade de Odontologia de Bauru. Departamento de Ortodontia - Brasil
[4] Universidade de São Paulo. Faculdade de Odontologia de Bauru. Departamento de Ortodontia - Brasil
[5] Universidade de São Paulo. Faculdade de Odontologia de Bauru. Departamento de Ortodontia - Brasil
[6] Universidade de São Paulo. Faculdade de Odontologia de Bauru. Departamento de Ortodontia - Brasil
[7] Universidade de São Paulo. Faculdade de Odontologia de Bauru. Departamento de Ortodontia - Brasil
Número total de Afiliações: 7
Tipo de documento: Artigo Científico
Fonte: Dental Press J. Orthod.; v. 25, n. 6, p. 33-42, 2021-01-20.
Resumo

ABSTRACT Introduction: Controversial reports suggest a relationship between growth pattern and cortical alveolar bone thickness, and its effect in the use of mini-implants. Objective: The main purpose of this study was to assess the influence of the growth pattern on the cortical alveolar bone thickness and on the stability and success rate of mini-implants. Methods: Fifty-six mini-implants were inserted in the buccal region of the maxilla of 30 patients. These patients were allocated into two groups, based on their growth pattern (horizontal group [HG] and vertical group [VG]). Cortical thickness was measured using Cone Beam Computed Tomography. Stability of mini-implants, soft tissue in the insertion site, sensitivity during loading and plaque around the mini-implants were evaluated once a month. Intergroup comparisons were performed using t tests, Mann-Whitney tests, and Fisher exact tests. Correlations were evaluated with Pearson’s correlation coefficient. Results: The cortical bone thickness was significantly greater in the HG at the maxillary labial anterior region and at the mandibular buccal posterior and labial anterior regions. There was a significant negative correlation between Frankfort-mandibular plane angle (FMA) and the labial cortical thickness of the maxilla, and with the labial and lingual cortical bone thicknesses of the mandible. No significant intergroup difference was found for mini-implant mobility and success rate. No associated factor influenced stability of the mini-implants. Conclusions: Growth pattern affects the alveolar bone cortical thickness in specific areas of the maxilla and mandible, with horizontal patients presenting greater cortical bone thickness. However, this fact may have no influence on the stability and success rate of mini-implants in the maxillary buccal posterior region. (AU)

Processo FAPESP: 09/06925-0 - Influência do padrão de crescimento sobre a espessura da ccortical óssea alveolar e sua correlação com a estabilidade dos mini-implantes
Beneficiário:Carolina Carmo de Menezes
Modalidade de apoio: Bolsas no Brasil - Mestrado