Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Evaluating Sensitivity to Clogging by Solid Particles in Irrigation Emitters: Assessment of a Laboratory Protocol

Texto completo
Autor(es):
de Sousa Pereira, Diego Jose [1] ; Lavanholi, Rogerio [1] ; de Araujo, Ana C. S. [1] ; de Camargo, Antonio P. [2] ; Ait-Mouheb, Nassim [3, 4] ; Frizzone, Jose A. [1] ; Molle, Bruno [3, 4]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Coll Agr Luiz de Queiroz, Dept Biosyst Engn, BR-13418900 Piracicaba, SP - Brazil
[2] Univ Estadual Campinas, Agr Engn Coll, FEAGRI UNICAMP, Ave Candid Rondon 501, BR-13083875 Campinas, SP - Brazil
[3] Univ Montpellier, Joint Res Unit Water Management Actors Terr, French Natl Inst Agr Food & Environm, Dept Waters, F-34196 Montpellier - France
[4] Univ Montpellier, Dept Waters, UMR G Eau, F-34196 Montpellier - France
Número total de Afiliações: 4
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF IRRIGATION AND DRAINAGE ENGINEERING; v. 146, n. 11 NOV 1 2020.
Citações Web of Science: 0
Resumo

As drip irrigation develops rapidly worldwide, the need for a standardized method to evaluate emitters' clogging sensitivity is reinforced. Methodologies for evaluating the sensitivity of emitters to clogging enable identification of trends in the change in performance of emitters operated under clogging risk, selection of emitter designs with higher performance for a given set of water characteristics, and recommendation of a consistent filtration method and maintenance routines. In this study, a clogging test protocol for evaluating the sensitivity of emitters to clogging caused by suspended solid particles was assessed to improve the reliability of test results and analyze the impact of sample size (number of emitters) on clogging result accuracy. Two models of integrated non-pressure-compensating emitters were tested in three replications. The 160-h clogging test procedure consisted of four 40-h stages that varied in size and concentration of solid suspended particles. The results enabled accurate assessment of the combination of size and concentration of particles that caused clogging in each emitter model, thereby revealing trends in the sensitivity of emitters to clogging, which were not dependent on emitter sample size. Recommendations for an international standardized clogging test protocol are proposed. (AU)

Processo FAPESP: 15/19630-0 - Processos de obstrução de emissores de irrigação causados por partículas sólidas
Beneficiário:Jose Antonio Frizzone
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 18/20099-5 - Processos de obstrução de gotejadores para irrigação por interações entre carbonato de cálcio e partículas sólidas
Beneficiário:Antonio Pires de Camargo
Modalidade de apoio: Auxílio à Pesquisa - Regular