Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Paper microfluidic device using carbon dots to detect glucose and lactate in saliva samples

Texto completo
Autor(es):
Rossini, Eduardo Luiz [1] ; Milani, Maria Izabel [1] ; Lima, Liliane Spazzapam [1] ; Pezza, Helena Redigolo [1]
Número total de Autores: 4
Afiliação do(s) autor(es):
[1] Univ Estadual Paulista Julio de Mesquita Filho UN, Inst Quim, Rua Prof Francisco Degni 55, CP 355, BR-14800900 Araraquara, SP - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY; v. 248, MAR 5 2021.
Citações Web of Science: 0
Resumo

Bioanalyses are commonly performed with blood or serum samples. However, these analyses often require invasive and painful blood collection using a needle or finger pricking. Saliva is an alternative and very attractive biological medium for performing clinical analyses, since it contains many types of clinically relevant biomarkers and compounds. Its collection is straightforward and can be achieved in a non-invasive and stress-free way. However, the analytes are frequently present at low concentrations, while the viscosity of whole saliva hinders its analysis using paper devices, especially those with multiple layers (3D-lPADs). This work explores the use of a simple, fast, and low-cost saliva sample pretreatment using a cotton-paper-syringe filtration system, allowing the analysis of saliva samples using multilayer paper devices. The proposed methodology employs the oxidation of glucose and lactate, catalyzed by specific oxidase enzymes, producing hydrogen peroxide. The detection is based on the fluorescence quenching of carbon dots in the presence of hydrogen peroxidase. The concentrations of the analytes showed good linear correlations with the fluorescence quenching, with LODs of 2.60 x 10(-6) and 8.14 x 10(-7) mol L-1 for glucose and lactate, respectively. The proposed method presented satisfactory intra-day and inter-day repeatabilities, with %RSD values in the range 3.82-6.61%. The enzymatic systems proved to be specific for the analytes and the matrix had no significant influence on the glucose and lactate determinations. The proposed methodology was successfully applied to saliva and serum samples and was validated using certified material. (C) 2020 Elsevier B.V. All rights reserved. (AU)

Processo FAPESP: 15/21733-1 - Desenvolvimento de métodos analíticos de vanguarda utilizando spot test e dispositivo microfluidico em papel.
Beneficiário:Helena Redigolo Pezza
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 16/20847-6 - Desenvolvimento de dispositivo analítico microfluídico em papel para análises de interesse clínico com detecção por fluorescência
Beneficiário:Eduardo Luiz Rossini
Modalidade de apoio: Bolsas no Brasil - Doutorado