Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Silica-Nylon Reinforcement Effect on the Fracture Load and Stress Distribution of a Resin-Bonded Partial Dental Prosthesis

Texto completo
Autor(es):
Firmino, Aline Silva [1] ; Tribst, Joao Paulo Mendes [2, 3] ; Nakano, Leonardo Jiro Nomura [1] ; Dal Piva, Amanda Maria de Oliveira [2, 3] ; Borges, Alexandre Luiz Souto [2, 3] ; Arruda Paes-Junior, Tarcisio Jose [1]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Sao Paulo State Univ Unesp, Inst Sci & Technol, Dept Dent Mat & Prosthodont, Sao Jose Dos Campos, SP - Brazil
[2] Vrije Univ, Gustav Mahlerlaan 3004, NL-1081 LA Amsterdam, Noord Holland - Netherlands
[3] Univ Amsterdam, Acad Ctr Dent Amsterdam, Dept Dent Mat Sci, Gustav Mahlerlaan 3004, NL-1081 LA Amsterdam, Noord Holland - Netherlands
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY; v. 41, n. 2, p. E45-E54, MAR-APR 2021.
Citações Web of Science: 0
Resumo

This study investigated the influence of silica-nylon reinforcement on the stress distribution and fracture load of a resin-bonded fixed partial dental prosthesis (RBFDP). Three-unit RBFDPs (N = 60) were inserted between the first premolar and the first molar of a maxillary model. The groups were divided according to the nylon reinforcement (n = 20/group): conventional fixed prosthesis (without reinforcement), prosthesis with silica-nylon reinforcement positioned vertically, and prosthesis with silica-nylon reinforcement positioned horizontally. Half of the specimens were tested after 24 hours in a universal testing machine until fracture (1,000 kgf; 1 mm/minute) to determine the single load to fracture. The other half was submitted to mechanical aging during 10(6) cycles (100 N, 2 Hz), totaling 6 groups (n = 10/group). The results were analyzed by two-way analysis of variance (ANOVA; alpha = 5%). The stress distribution for non-aged groups was simulated using finite element analysis. The numeric prostheses were modeled similarly to the in vitro assay. ANOVA showed no statistical difference between groups (P<.05) for load to fracture. However, the use of the reinforcement provided stability even after the failure, as the parts did not separate. The computational analysis showed similar biomechanical behavior among the groups. The use of the nylon reinforcement does not influence the fracture load or the stress distribution, but it does enable the prosthesis to remain in position after failure. (AU)

Processo FAPESP: 11/07334-6 - Influência da utilização de uma fibra de nylon modificada na resistência à flexão e alteração dimensional de resinas acrílicas
Beneficiário:Tarcisio Jose de Arruda Paes Junior
Modalidade de apoio: Auxílio à Pesquisa - Regular