Efficiency of a digital electrofulguration system in contaminated root canals in vitro

Texto completo
Autor(es):
Cimara B. B. Silva [1] ; Juliana D. Bronzato [2] ; Daniel R. Herrera ; Francisco Montagner ; Elifas L. Nunes ; Brenda P F A Gomes [6]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] State University of Amazonas. Department of Endodontics - Brasil
[2] State University of Campinas. Piracicaba Dental School. Department of Restorative Dentistry, Division of Endodontics - Brasil
[6] State University of Campinas. Piracicaba Dental School. Department of Restorative Dentistry, Division of Endodontics - Brasil
Número total de Afiliações: 6
Tipo de documento: Artigo Científico
Fonte: Brazilian Dental Journal; v. 32, n. 3, p. 1-9, 2021-11-08.
Resumo

Abstract Decontamination of the root canal (RC) system is essential for successful endodontic therapy. In this in vitro study, it was evaluated the disinfection potential of an electrofulguration device, the Endox® Endodontic System (EES), in RC infected with Enterococcus faecalis. Sixty-five human lower premolars were instrumented with MTwo® system. The specimens were distributed into six experimental groups (n = 10), according to the irrigation protocol: 2% chlorhexidine gel (CHX); CHX + EES; 5.25% sodium hypochlorite (NaOCl); NaOCl + EES; saline solution (SS); and SS + EES. Five specimens were untreated (control). RC samples were collected before (C1) and after EES treatment (C2), after chemo-mechanical preparation (CMP) (C3), and after final EES treatment (C4). All samples were plated for colony forming units (CFU/mL) onto solid media. The data were analyzed by Wilcoxon and Friedman tests for intragroup comparisons and by Kruskal Wallis test followed by Dunn’s test for intergroup comparisons (α = 0.05). Treatment with the EES did not significantly reduce the number of CFU/mL as compared to baseline levels (C1 vs. C2, p> 0.05). After CMP (C3), all groups showed a significantly reduced amount of CFU/mL (p <0.05), with no difference between CHX- and NaOCl-treated samples (p >0.05). Lastly, treatment with the EES following CMP (C4) did not significantly reduce the amount of CFU/mL (C3 vs. C4, p> 0.05). To conclude, the use of the Endox® Endodontic System did not result in considerable bacterial reduction at all operative times, while treatment with NaOCl and CHX was equally efficient for this purpose. (AU)