Busca avançada
Ano de início
Entree


Advanced tuning of the ion management parameters in GC x GC-HRMS using a Fourier transform Orbitrap mass analyzer for pixel-based data handling and multivariate analysis

Texto completo
Autor(es):
Moreira de Oliveira, Amilton ; Teixeira, Carlos Alberto ; Hantao, Leandro Wang
Número total de Autores: 3
Tipo de documento: Artigo Científico
Fonte: ANALYTICAL METHODS; v. 14, n. 16, p. 9-pg., 2022-04-04.
Resumo

GC x GC investigations are well known to generate a substantial amount of information-rich and structurally complex data, requiring advanced data processing strategies like chemometrics. Many workflows are available for data handling and processing, such as the peak-table and pixel-based approaches. The goal of this work is to present a solution based on method development to solve the missing pixel problem that may be encountered in experiments performed with GC and GC x GC coupled to the Fourier transform orbital ion trap (FT-Orbitrap) mass analyzer. Data input is vital for pixel-based chemometric analyses, as some post-processing solutions may lead to significant loss of chemical information in the data set. Hence, a key requisite is that the chemical information is consistently indexed in the data arrays for proper pixel-based data handling and analysis. In this study, we carefully evaluated the ion management parameters to preserve the intrinsic structure and information of the data arrays of the GC x GC-FT-Orbitrap for future pixel-oriented chemometric analysis. The most acceptable conditions yielded acquisition rates up to 42.6 spectra per s, while a routine setting of 24.7 Hz was successfully employed in analyses of different petroleum fractions, producing both consistent tensor sizes and acceptable peak reconstructions. A data acquisition rate of 24.7 spectra per s and a mass resolving power of 15 000 allowed the resolution of a mass split of only 0.004 Da - which is an interesting configuration for challenging applications in petroleomics. Using such advanced settings, the missing pixel problem was reduced from up to 30% to much less than 0.04% of the data array dimension. Thus, the proposed configuration can be employed in studies that require pixel-oriented multivariate data analysis. (AU)

Processo FAPESP: 19/11353-8 - Centro Brasileiro de Pesquisa em Água (BWRC)
Beneficiário:Lauro Tatsuo Kubota
Modalidade de apoio: Auxílio à Pesquisa - Programa Centros de Pesquisa em Engenharia
Processo FAPESP: 20/01064-6 - Desenvolvimentos analíticos visando estudos com amostras reais do derrame de petróleo na costa litorânea de Pernambuco: simulações, caracterizações químicas e bioensaios de ecotoxicidade
Beneficiário:Leandro Wang Hantao
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 14/50867-3 - INCT 2014: Instituto Nacional de Ciência e Tecnologia de Bioanalítica
Beneficiário:Marco Aurelio Zezzi Arruda
Modalidade de apoio: Auxílio à Pesquisa - Temático