Busca avançada
Ano de início
Entree


Laser Ablation of Benign Thyroid Nodules: A Prospective Pilot Study With a Preliminary Analysis of the Employed Energy

Texto completo
Autor(es):
Costa de Freitas, Ricardo Miguel ; Miazaki, Aline Paterno ; Tsunemi, Miriam Harumi ; Furtado de Araujo Filho, Vergilius Jose ; Marui, Suemi ; Seguro Danilovic, Debora Lucia ; Buchpiguel, Carlos Alberto ; Chammas, Maria Cristina
Número total de Autores: 8
Tipo de documento: Artigo Científico
Fonte: Lasers in Surgery and Medicine; v. 52, n. 4, p. 10-pg., 2019-07-25.
Resumo

Background and Objectives To assess the effectiveness of ultrasound (US)-guided laser ablation of benign thyroid nodules (TNs) under different amounts of applied energy. Study Design/Materials and Methods Thirty-four euthyroid patients with 5-18 ml TNs were enrolled: 21 (laser ablation) and 13 (clinical follow up) patients with a mean age of 56.2 +/- 12.0 and 54.7 +/- 14.7 years, respectively. The laser ablation protocol used a 1.064 mm wavelength diode laser source; 3.5 W output power; 1,100-1,500 J and 5-8 min/illumination; and one or two fibers/session. Clinical, laboratory, and US data were obtained immediately before treatment and at 6 and 12 months follow-up and were analyzed by Student's t test and Fisher's exact test. Low- and high-energy subgroups were subsequently defined, and the receiver operating characteristic (ROC) curves were calculated. Results Laser ablation follow-up showed an overall nodule volume reduction of more than 50%; improvement of symptoms and cosmetic complaints (P = 0.001); and stable laboratory data compared with the baseline and control groups. Minor complications were 9.5% (n = 2). One or two fibers/session resulted in a similar nodule volume reduction among 10-18 ml nodules. Analysis of the applied energy suggested a 398.8 J/ml inferior cutoff (ROC curve: 0.889 sensitivity; 0.545 specificity) for the high-energy subgroup (n = 14, mean 599.9 +/- 136.5 J/ml) to reduce the nodule volume over time (-55.1% vs. -58.4%, P = 0.55). The low-energy subgroup (n = 7, mean 240.2 +/- 74.6 J/ml) did not show a persistent volume reduction (P < 0.05) from the 6- to 12-month follow-ups (-56.6% vs. -53.7%). Conclusions Laser ablation of benign TNs achieved technique efficacy at 12 months posttreatment, with clinical improvement and few minor side effects. A single fiber in a single session with a high deployed energy (>398.8 J/ml) may be associated with improved results, a finding to be confirmed with a larger series. Lasers Surg. Med. (c) 2019 Wiley Periodicals, Inc. (AU)

Processo FAPESP: 12/50274-7 - Tratamento de nodulos tireoideanos benignos com ablacao percutanea a laser versus acompanhamento.
Beneficiário:Maria Cristina Chammas
Modalidade de apoio: Auxílio à Pesquisa - Regular