Busca avançada
Ano de início
Entree


Bone tissue formation around two titanium implant surfaces placed in bone defects filled with bone substitute material or blood clot: A pilot study

Texto completo
Autor(es):
Trento, Guilherme dos Santos ; Spin-Neto, Rubens ; Farnezi Bassi, Ana Paula ; Okamoto, Roberta ; Cabrini Gabrielli, Marisa Aparecida ; Pereira-Filho, Valfrido Antonio
Número total de Autores: 6
Tipo de documento: Artigo Científico
Fonte: CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH; v. 21, n. 6, p. 6-pg., 2019-11-06.
Resumo

ObjectivesThe objective of this study was to evaluate the peri-implant bone tissue formation around titanium implants with different surface treatments, placed in bone defects filled or not with bone substitute material (BSM). Materials and MethodsTen animals were divided into two groups according to implant surface treatment. In each tibia, a bone defect was created followed by the placement of one implant. On the left tibia, the defect was filled with blood clot (BC), and on the right tibia, the defect was filled with biphasic hydroxyapatite/beta-tricalcium-phosphate (HA/TCP) generating four subgroups: BC-N: blood clot and porous surface; BC-A: blood clot and porous-hydrophilic surface; HA/TCP-N: BSM and porous surface; HA/TCP-A: BSM and porous-hydrophilic surface. The animals were submitted to euthanasia 60days after implant installation. After light-curing resin inclusion, the blocks containing the implant and the bone tissue were stained and evaluated by means of histomorphometry to assess the percentages of bone implant contact (% BIC). Data was normally distributed and the group differences were examined using the parametric tests of Two-Way ANOVA. ResultsThe BC-A group presented the higher mean value of BIC (46.43%). The HA/TCP-A group presented the higher mean value of BIC. The porous-hydrophilic surfaces presented better results of BIC when compared to the porous surface in both conditions of defect filling. No statistically significant differences were found among all groups (95% confidence interval and P<.05). ConclusionAccording to histomorphometric analysis, after 60-days in a rabbit model, hydrophilic and hydrophobic surfaces have the same behavior in the presence or absence of HA/TCP. (AU)

Processo FAPESP: 17/04017-6 - Avaliação da osseointegração, por meio de análise celular, em implantes de titânio de diferentes superfícies, instalados em áreas de defeito ósseo preenchidos ou não com biomaterial
Beneficiário:Valfrido Antonio Pereira Filho
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 16/07837-1 - Avaliação da osseointegração, por meio de análise celular, em implantes de titânio de diferentes superfícies, instalados em áreas de defeito ósseo preenchidos ou não com biomaterial
Beneficiário:Guilherme dos Santos Trento
Modalidade de apoio: Bolsas no Brasil - Doutorado Direto