Flow injection analysis of free glycerol in biodiesel using a copper electrode as an amperometric detector

Texto completo
Autor(es):
Maruta, Aleksander H. [1] ; Paixao, Thiago R. L. C. [1, 2]
Número total de Autores: 2
Afiliação do(s) autor(es):
[1] Univ Fed ABC, Ctr Ciencias Nat & Humanas, BR-09210170 Santo Andre, SP - Brazil
[2] Univ Sao Paulo, Inst Quim, BR-05508900 Sao Paulo - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: FUEL; v. 91, n. 1, p. 187-191, JAN 2012.
Citações Web of Science: 19
Resumo

The main goal of this work was to develop a simple analytical method for quantification of glycerol based on the electrocatalytic oxidation of glycerol on the copper surface adapted in a flow injection system. Under optimal experimental conditions, the peak current response increases linearly with glycerol concentration over the range 60-3200 mg kg(-1) (equivalent to 3-160 mg L(-1) in solution). The repeatability of the electrode response in the flow injection analysis (FIA) configuration was evaluated as 5% (n = 10), and the detection limit of the method was estimated to be 5 mg kg(-1) in biodiesel (equivalent to 250 mu g L(-1) in solution) (S/N = 3). The sample throughput under optimised conditions was estimated to be 90 h(-1). Different types of biodiesel samples (B100), as in the types of vegetable oils or animal fats used to produce the fuels, were analysed (seven samples). The only sample pre-treatment used was an extraction of glycerol from the biodiesel sample containing a ratio of 5 mL of water to 250 mg of biodiesel. The proposed method improves the analytical parameters obtained by other electroanalytical methods for quantification of glycerol in biodiesel samples, and its accuracy was evaluated using a spike-and-recovery assay, where all the biodiesel samples used obtained admissible values according to the Association of Official Analytical Chemists. Crown Copyright (C) 2011 Published by Elsevier Ltd. All rights reserved. (AU)

Processo FAPESP: 09/07859-1 - Desenvolvimento de línguas eletrônicas voltamétricas visando à caracterização e identificação de processos de adulteração e falsificação em biocombustíveis
Beneficiário:Thiago Regis Longo Cesar da Paixão
Modalidade de apoio: Auxílio à Pesquisa - Regular