Studies of the Electrochemical Degradation of Acet... - BV FAPESP
Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Studies of the Electrochemical Degradation of Acetaminophen Using a Real-Time Biomimetic Sensor

Texto completo
Autor(es):
Quintino de Oliveira, Mariana Calora [1] ; Tanaka, Auro Atsushi [2] ; Roberto de Vasconce los Lanza, Marcos [3] ; Taboada Sotomayor, Maria Del Pilar [1]
Número total de Autores: 4
Afiliação do(s) autor(es):
[1] State Univ Sao Paulo UNESP, Dept Analyt Chem, Inst Chem, BR-14801970 Araraquara, SP - Brazil
[2] Fed Univ Maranhao UFMA, Ctr Phys Sci & Technol, BR-65085580 Sao Luis, MA - Brazil
[3] Univ Sao Paulo, Dept Mol Phys Chem IQSC, BR-13560970 Sao Carlos, SP - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: Electroanalysis; v. 23, n. 11, p. 2616-2621, NOV 2011.
Citações Web of Science: 2
Resumo

Real-time monitoring of the electrochemical degradation of acetaminophen was performed using a biomimetic sensor coupled to a flow injection analysis (FIA) system. Degradation of the drug was carried out at constant current density (24 to 180 mAcm(-2)) in an electrolyte consisting of 0.1 molL(-1) K(2)SO(4)/5.0 x 10(-4) molL(-1) FeSO(4)center dot 7H(2)O. Two commercial DSA anodes (DSA-Cl(2) and DSA-O(2)) were compared. The degradation process was monitored online using an amperometric sensor based on the biomimetic catalyst iron(III) tetrapyridinoporphyrazine (FeTPyPz), coupled to the degradation cell. The optimized FIA detection system employed the electrolyte solution as carrier, a flow rate of 1.25 mLmin(-1) and an injected sample volume of 75 mu L. The real-time data obtained showed, as expected, that acetaminophen degradation followed pseudo-first order kinetics, with the DSA-Cl(2) anode showing a higher efficiency according to the calculated apparent rate constant values. The advantage of the proposed on-line system is that a larger number of points can be monitored in a shorter time compared to other off-line methods, which improves the accuracy of estimates of electrochemical degradation constants. (AU)

Processo FAPESP: 08/00303-5 - Construção de sensores biomiméticos para determinação de fármacos e seu acoplamento a sistemas em fluxo
Beneficiário:Maria Del Pilar Taboada Sotomayor
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 07/08314-3 - Degradação de pesticidas organofosforados (clorpirifós, paration-metílico e profenofós) via processos eletroquímicos / processos oxidativos avançados
Beneficiário:Marcos Roberto de Vasconcelos Lanza
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 08/05899-3 - Acoplamento de um Sensor Biomimético com um Reator Eletroquímico para Monitoramento "on line" da Degradação Eletroquímica de Paracetamol
Beneficiário:Mariana Calora Quintino de Oliveira
Modalidade de apoio: Bolsas no Brasil - Iniciação Científica