Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do SciELO, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Shaping ability of a pediatric motor-driven instrumentation system in primary molar root canal prototypes

Texto completo
Autor(es):
Bianca Katsumata de Souza [1] ; Murilo Priori Alcalde [2] ; Marco Antonio Hungaro Duarte [3] ; Maria Aparecida Andrade Moreira Machado [4] ; Thais Marchini Oliveira [5] ; Natalino Lourenço Neto [6]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] University of São Paulo - Brasil
[2] University of São Paulo - Brasil
[3] University of São Paulo - Brasil
[4] University of São Paulo - Brasil
[5] University of São Paulo - Brasil
[6] University of São Paulo - Brasil
Número total de Afiliações: 6
Tipo de documento: Artigo Científico
Fonte: Brazilian Dental Journal; v. 34, n. 5, p. 36-42, 2023-12-22.
Resumo

Abstract Evaluate the shaping ability and preparation time using a pediatric motor-driven rotary instrumentation compared to other systems in resin prototypes of primary molars. Methods: Thirty specimens were scanned in micro-CT and divided into three groups according to the instrumentation type: pediatric motor-driven Sequence baby File (SBF); conventional motor-driven (Sequence Rotary File - SRF); manual K file. Instrumentation time was timed. After preparation, the specimens were scanned again. The pre- and post-instrumentation images were superimposed to measure the amount of root canal deviation and the resin remnant thickness. ANOVA followed by the Tukey test analyzed the comparisons between groups (p<0.05). Results: No statistically significant differences occurred in root canal deviation among groups (p>0.05). There were statistically significant differences in the comparison among root thirds (p<0.001) but without significant differences in the interaction group vs. root third (p>0.05). Both motor-driven instrumentations showed statistically greater weariness than manual instrumentation (p<0.001), without significant significant differences between SBF and SRF. Motor-driven instrumentation had a shorter working time than manual instrumentation (p<0.001). Conclusion: Pediatric motor-driven instrumentation demonstrated good outcomes in relation to root canal deviation and amount of remnant structure, with shorter instrumentation time. SBF can be a suitable alternative for endodontic instrumentation in primary molars. (AU)

Processo FAPESP: 21/06342-7 - Comparação entre instrumentação manual, mecanizada, mecanizada odontopediátrica e reciprocante na qualidade de preparo, tempo e segurança em molares decíduos prototipados
Beneficiário:Natalino Lourenço Neto
Modalidade de apoio: Auxílio à Pesquisa - Regular