Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Effects of stress relaxation in beta-titanium orthodontic loops

Texto completo
Autor(es):
Fernandes Rabelo Caldas, Sergei Godeiro [1] ; Martins, Renato Parsekian [2] ; Viecilli, Rodrigo F. [3] ; Galvao, Marilia Regalado [1] ; Martins, Lidia Parsekian [1]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Univ Estadual Paulista, Fac Odontol Araraquara, Sao Paulo - Brazil
[2] Sao Paulo State Univ, Araraquara Sch Dent, UNESP, Orthodont Grad Program, Sao Paulo - Brazil
[3] NYU, Coll Dent, Dept Orthodont, New York, NY - USA
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS; v. 140, n. 2 AUG 2011.
Citações Web of Science: 6
Resumo

Introduction: This study evaluates the changes in the force system of the beta-titanium T-loop spring (TLS) caused by stress relaxation. Methods: Ninety TLSs with dimensions of 6 x 10 mm, made of 0.017 x 0.025 in beta-titanium alloy and preactivated by concentrated bends, were randomly distributed into 9 groups according to the time point of evaluation. Group 1 was tested immediately after spring preactivation and stress relief by trial activation. The other 8 groups were tested after 24, 48, and 72 hours, and 1, 2, 4, 8, and 12 weeks. By using a moment transducer coupled to a digital extensometer indicator adapted to a universal testing machine, the amounts of horizontal forces and moments and the moment-to-force ratios were recorded at every 0.5 mm of deactivation from 5 mm of the initial activation in an interbracket distance of 23 mm. Results: The horizontal forces and moments were higher (P < 0.001) for group 1 compared with the other 8 groups, which were not different among themselves. All groups produced similar moment-to-force ratios (P 5 0.600), with no influence of time. Conclusions: The TLSs preactivated by concentrated bends had progressive load decreases over time, and this effect is critical in the first 24 hours. (Am J Orthod Dentofacial Orthop 2011;140:e85-e92) (AU)

Processo FAPESP: 08/07258-5 - Avaliação da estabilidade das pré-ativações das molas "T" do Grupo B confeccionadas com fios de titânio-molibdênio ao longo de três meses
Beneficiário:Lídia Parsekian Martins
Modalidade de apoio: Auxílio à Pesquisa - Regular