Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Ablation Rate and Morphology of Superficial and Deep Dentin Irradiated with Different Er:YAG Laser Energy Levels

Texto completo
Autor(es):
Raucci-Neto, Walter [1] ; Chinelatti, Michelle Alexandra [1] ; Palma-Dibb, Regina Guenka [1]
Número total de Autores: 3
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Fac Odontol Ribeirao Preto, Sch Dent Ribeirao Preto, Dept Restorat Dent, Sao Paulo - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: Photomedicine and Laser Surgery; v. 26, n. 6, p. 523-529, DEC 2008.
Citações Web of Science: 11
Resumo

Objective: In this study we evaluated the ablation rate of superficial and deep dentin irradiated with different Er:YAG laser energy levels, and observed the micromorphological aspects of the lased substrates with a scanning electron microscope (SEM). Background Data: Little is known about the effect of Er: YAG laser irradiation on different dentin depths. Materials and Methods: Sixty molar crowns were bisected, providing 120 specimens, which were randomly assigned into two groups ( superficial or deep dentin), and later into five subgroups (160, 200, 260, 300, or 360 mJ). Initial masses of the specimens were obtained. After laser irradiation, the final masses were obtained and mass losses were calculated followed by the preparation of specimens for SEM examination. Mass-loss values were subjected to two-way ANOVA and Fisher's least significant difference multiple-comparison tests (p < 0.05). Results: There was no difference between superficial and deep dentin. A significant and gradual increase in the mass-loss values was reached when energies were raised, regardless of the dentin depth. The energy level of 360 mJ showed the highest values and was statistically significantly different from the other energy levels. The SEM images showed that deep dentin was more selectively ablated, especially intertubular dentin, promoting tubule protrusion. At 360 mJ the micromorphological features were similar for both dentin depths. Conclusion: The ablation rate did not depend on the depth of the dentin, and an energy level lower than 360 mJ is recommended to ablate both superficial and deep dentin effectively without causing tissue damage. (AU)

Processo FAPESP: 04/15612-2 - Influencia da energia do laser er:yag na capacidade de ablacao e morfologia da dentina superficial e profunda.
Beneficiário:Walter Raucci Neto
Modalidade de apoio: Bolsas no Brasil - Iniciação Científica