Photoelastic Analysis of Biomechanical Behavior of... - BV FAPESP
Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Photoelastic Analysis of Biomechanical Behavior of Single and Multiple Fixed Partial Prostheses With Different Prosthetic Connections

Texto completo
Autor(es):
Tonella, Bianca Piccolotto [1] ; Pellizzer, Eduardo Piza [1] ; Falcon-Antenucci, Rosse Mary [1] ; Ferraco, Renato [1] ; de Faria Almeida, Daniel Augusto [1]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Sao Paulo State Univ UNESP, Aracatuba Sch Dent, Dept Dent Mat & Prosthodont, Sao Paulo - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF CRANIOFACIAL SURGERY; v. 22, n. 6, p. 2060-2063, NOV 2011.
Citações Web of Science: 12
Resumo

The aim of this study was to evaluate the stress distribution on external hexagon, internal hexagon, and Morse taper implant in single and 3-unit implant-supported fixed partial prostheses (FPPs) using photoelasticity. Six models were fabricated with the photoelastic resin PL-2: 3 models for the 3-unit implant-supported FPP with implants of 4.0 x 10.0 mm in the region of the second premolar and molar including 1 model for each type of implant connection, and 3 models for the single prosthesis for each implant type. The prostheses fabrication was standardized. A circular polariscope was used, and axial and oblique (45 degrees) loads of 100 N were applied in a universal testing machine. The results were photographed and analyzed qualitatively. The internal hexagon implant exhibited better stress distribution and lower intensity of fringes followed by the external hexagon and Morse taper implants for the models with the 3-unit prostheses. For the single implants, the Morse taper implant presented better stress distribution, followed by the internal and external hexagon implants. The oblique loading increased the number of photoelastic fringes in all models. It was concluded that the internal hexagon implant exhibited better biomechanical behavior for the 3-unit implant-supported FPP, whereas the Morse taper implant was more favorable for the single implant-supported prosthesis. The oblique loading increased the stress in all models. (AU)

Processo FAPESP: 07/55061-3 - Análise das tensões em próteses parafusadas e cimentadas com implantes osseointegrados do tipo hexágono externo, interno e cone morse: estudo pelo método da fotoelasticidade
Beneficiário:Eduardo Piza Pellizzer