Mechanical properties and degree of conversion of etch-and-rinse and self-etch adhesive systems cured by a quartz tungsten halogen lamp and a light-emitting diode

Texto completo
Autor(es):
Gaglianone, Livia Aguilera [1] ; Lima, Adriano Fonseca [1, 2] ; Goncalves, Luciano Souza [3] ; Cavalcanti, Andrea Nobrega [4] ; Baggio Aguiar, Flavio Henrique [1] ; Marchi, Giselle Maria [1]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Restorat Dent, BR-13414903 Piracicaba, SP - Brazil
[2] Nove de Julho Univ, Sch Dent, Dept Restorat Dent, Sao Paulo - Brazil
[3] Univ Uberaba, Sch Dent, BR-38010200 Uberaba, MG - Brazil
[4] Sch Med & Publ Hlth Bahia EBMSP, Sch Dent, Dept Oral Rehabil, BR-41150100 Salvador, BA - Brazil
Número total de Afiliações: 4
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS; v. 12, p. 139-143, AUG 2012.
Citações Web of Science: 17
Resumo

The aim of the present study was to evaluate the degree of conversion (DC), elastic modulus (E), and flexural strength (FS) of five adhesive systems (only the bonding component of both Scotchbond MP-SBMP and Clearfil Protect Bond-CP; Single Bond 2-SB2; One-up Bond F Plus-OUP; and P90 System Adhesive: primer-P90P and bond-P90B) cured with a quartz tungsten halogen (QTH) lamp and a light-emitting diode (LED). Two groups per adhesive were formed (n = 5), according to the light source (quartz tungsten halogen - QTH: Demetron LC; and light-emitting diode - LED: UltraLume 5). Bar-shaped specimens were evaluated using three-point bending. The DC was obtained by Fourier transform infrared spectroscopy (FTIR). SB2 and P90P exhibited better DC values for QTH curing. However, SB2 and P90P presented the worst results overall. The light source was statistically significant for all adhesives, except for P90B and OUP. Non-solvated adhesives presented the best E and FS values. It could be concluded that the DC and E values can be influenced by the light source; however, this interference is material dependent. (C) 2012 Elsevier Ltd. All rights reserved. (AU)

Processo FAPESP: 09/15589-4 - Influência de diferentes fontes de luz, distâncias de ativação e armazenagem nas propriedades mecânicas de diferentes sistemas adesivos.
Beneficiário:Giselle Maria Marchi
Modalidade de apoio: Auxílio à Pesquisa - Regular
Processo FAPESP: 09/03763-0 - Influência de diferentes fontes de luz, distâncias de ativação e armazenagem nas propriedades mecânicas de diferentes sistemas adesivos.
Beneficiário:Lívia Aguilera Gaglianone
Modalidade de apoio: Bolsas no Brasil - Mestrado