A prospective study on implants installed with flapless-guided surgery using the all-on-four concept in the mandible

Texto completo
Autor(es):
Landazuri-Del Barrio, R. A. [1] ; Cosyn, J. [2, 3] ; De Paula, W. N. [1] ; De Bruyn, H. [2, 3] ; Marcantonio, Jr., E. [1]
Número total de Autores: 5
Afiliação do(s) autor(es):
[1] Univ Estadual Paulista, UNESP, Araraquara Dent Sch, Dept Oral Diag & Surg, Araraquara, SP - Brazil
[2] Univ Ghent, Fac Med & Hlth Sci, Dept Periodontol & Oral Implantol, B-9000 Ghent - Belgium
[3] Free Univ Brussels VUB, Sch Dent Med, Dept Periodontol, Brussels - Belgium
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: Clinical Oral Implants Research; v. 24, n. 4, p. 428-433, APR 2013.
Citações Web of Science: 29
Resumo

Aim Clinical data are scarce on flapless-guided surgery in the mandible using the all-on-four concept. In addition, limited documentation exists on the latter under immediate loading conditions with a pre-fabricated implant bridge. The aim was to provide detailed documentation focusing on clinical and radiographic outcome and complications. Material and methods Sixteen systemically healthy non-smoking patients (10 women, 6 men, average age 59years) with sufficient bone volume in the mandible were operated via flapless-guided surgery using the all-on-four concept. Clinical and radiographic data and complications were registered at 3, 6 and 12months. Results The overall implant survival rate was 90% with a trend for higher failure of short implants (P=0.098). The mean bone level after 12months of function was 0.83mm with a maximum of 1.07mm. Technical complications were common (15/16 patients). These mainly related to a misfit between the pre-fabricated prosthesis and abutment(s) (13/16 patients). Conclusion If immediate loading of implants is pursued fabrication of the implant bridge should be based on actual impression of the implants at the time of surgery and not on their virtual position. (AU)

Processo FAPESP: 08/10549-1 - Influência da velocidade de perfuração na reabsorção óssea ao redor de implantes osseointegrados instalados com carga imediata mediante cirurgia guiada sem retalho: estudo clínico e radiográfico
Beneficiário:Elcio Marcantonio Junior
Modalidade de apoio: Auxílio à Pesquisa - Regular