Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Myocardial fibrosis detected by cardiac CT predicts ventricular fibrillation/ventricular tachycardia events in patients with hypertrophic cardiomyopathy

Texto completo
Autor(es):
Mostrar menos -
Shiozaki, Afonso Akio [1] ; Senra, Tiago [1] ; Arteaga, Edmund [2] ; Martinelli Filho, Martino [3] ; Pita, Cristiane Guedes [3] ; Avila, Luis Francisco R. [1] ; Parga Filho, Jose Rodrigues [1] ; Mady, Charles [2] ; Kalil-Filho, Roberto [1] ; Bluemke, David A. [4] ; Rochitte, Carlos Eduardo [1]
Número total de Autores: 11
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Sch Med, Heart Inst InCor, Cardiovasc Magnet Resonance & Computed Tomog Sect, Sao Paulo - Brazil
[2] Univ Sao Paulo, Sch Med, Heart Inst InCor, Cardiomyopathy Unit, Sao Paulo - Brazil
[3] Univ Sao Paulo, Sch Med, Heart Inst InCor, Pacemaker Clin, Sao Paulo - Brazil
[4] NIH, Ctr Clin, Bethesda, MD 20892 - USA
Número total de Afiliações: 4
Tipo de documento: Artigo Científico
Fonte: JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY; v. 7, n. 3, p. 173-181, MAY-JUN 2013.
Citações Web of Science: 33
Resumo

Background: Myocardial fibrosis (MF) occurs in up to 80% of subjects with asymptomatic or mildly symptomatic hypertrophic cardiomyopathy (HCM) and can constitute an arrhythmogenic substrate for re-entrant, life-threatening ventricular arrhythmias in predisposed persons. Objective: The aim was to investigate whether MF detected by delayed enhancement cardiac CT is predictive of ventricular tachycardia (VT) and fibrillation (VF) that require appropriate therapy by an implantable cardioverter defibrillator (ICD) in patients with HCM. Methods: Twenty-six patients with HCM with previously (for at least 1 year) implanted ICD underwent MF evaluation by cardiac CT. MF was quantified by myocardial delayed enhanced cardiac CT. Data on ICD firing were recorded every 3 months after ICD implantation. Risk factors for sudden cardiac death in patients with HCM were evaluated in all patients. Results: MF was present in 25 of 26 patients (96%) with mean fibrosis mass of 20.5 +/- 15.8 g. Patients with appropriate ICD shocks for VF/VT had significantly greater MF mass than patients without (29.10 +/- 19.13 g vs 13.57 +/- 8.31 g; P = .01). For a MF mass of at least 18 g, sensitivity and specificity for appropriate ICD firing were 73% (95% CI, 49%-88%) and 71% (95% CI, 56%-81%), respectively. Kaplan-Meier curves indicated a significantly greater VF/VT event rate in patients with MF mass >= 18 g than in patients with MF <18 g (P = .02). In the Cox regression analysis, the amount of MF was independently associated with VF/VT in ICD-stored electrograms. Conclusion: The mass of MF detected by cardiac CT in patients with HCM at high risk of sudden death was associated with appropriate ICD firings. (C) 2013 Society of Cardiovascular Computed Tomography. All rights reserved. (AU)

Processo FAPESP: 07/58876-8 - Tomografia computadorizada com múltiplos detectores e ressonância magnética na estratificação de risco da cardiomiopatia hipertrófica
Beneficiário:Carlos Eduardo Rochitte
Modalidade de apoio: Auxílio à Pesquisa - Regular