Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

ON and OFF Electroretinography and Contrast Sensitivity in Duchenne Muscular Dystrophy

Texto completo
Autor(es):
Salgueiro Barboni, Mirella Telles [1, 2] ; Nagy, Balazs Vince [3, 1, 2] ; de Araujo Moura, Ana Laura [1, 2] ; Damico, Francisco Max [1, 2, 4] ; da Costa, Marcelo Fernandes [1, 2] ; Kremers, Jan [5] ; Ventura, Dora Fix [1, 2]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Nucleo Neurociencias & Comportamento, Sao Paulo - Brazil
[2] Univ Sao Paulo, Inst Psicol, Dept Psicol Expt, Sao Paulo - Brazil
[3] Budapest Univ Technol & Econ, Dept Mechatron Opt & Engn Informat, Budapest - Hungary
[4] Univ Sao Paulo, Fac Med, Dept Oftalmol, Sao Paulo - Brazil
[5] Univ Hosp Erlangen, Dept Ophthalmol, Erlangen - Germany
Número total de Afiliações: 5
Tipo de documento: Artigo Científico
Fonte: INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE; v. 54, n. 5, p. 3195-3204, MAY 2013.
Citações Web of Science: 10
Resumo

PURPOSE. The study investigated possible asymmetric dysfunction of the ON and OFF visual mechanisms in DMD (Duchenne muscular dystrophy) patients associated with specific genetic alterations. METHODS. Nineteen DMD patients and 7 heterozygous DMD carriers were tested, as well as 19 age-matched controls. Full-field ERGs were recorded using mesopic (1 cd/m(2)) and photopic (250 cd/m(2)) sawtooth luminance modulations as stimuli: rapid increase and ramping decrease (to isolate ON responses) or rapid decrease and ramping increase (for OFF responses). In addition, a psychophysical study comprised contrast sensitivity tests using two checkerboard stimuli at either higher (ON) or lower (OFF) luminance relative to the background: 0.3 cycles per degree (cpd) presented for 33 ms (low spatial frequency, short duration) and 2 cpd presented for 1500 ms (high spatial frequency, long duration). RESULTS. A significant ERG amplitude reduction, relative to controls, was detected in the DMD patients in the mesopic positive peaks for both ON and OFF stimuli, as well as for the photopic ON stimulus (P < 0.05). Contrast sensitivity was significantly lower in the DMD patients (P < 0.05) relative to controls for the ON stimuli. Neither the ERG nor the contrast sensitivities were altered in the carriers. CONCLUSIONS. This study suggests that there are ON and OFF ERG alterations when both rods and cones contribute to the ERG responses in DMD patients. When only cones are activated there is an asymmetrical ERG alteration, also revealed by the contrast sensitivity measurements. (AU)

Processo FAPESP: 09/54292-7 - Avaliacao do desempenho visual em diferentes condicoes de iluminacao artificial com caracteristicas espectrais variadas
Beneficiário:Balazs Vince Nagy
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado
Processo FAPESP: 08/58731-2 - A visão como indicador de processos lesivos na retina e no sistema nervoso central
Beneficiário:Dora Selma Fix Ventura
Modalidade de apoio: Auxílio à Pesquisa - Temático
Processo FAPESP: 07/55125-1 - Avaliação eletrofisiológica e psicofísica das vias visuais on e off em jovens com Distrofia Muscular de Duchenne
Beneficiário:Mirella Telles Salgueiro Barboni
Modalidade de apoio: Bolsas no Brasil - Doutorado