Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Evaluation of sample preparation procedures and krypton as an interference standard probe for arsenic speciation by HPLC-ICP-QMS

Texto completo
Autor(es):
Amaral, Clarice D. B. [1, 2] ; Dionisio, Amalia G. G. [2] ; Santos, Mirian C. [3] ; Donati, George L. [2] ; Nobrega, Joaquim A. [2] ; Nogueira, Ana R. A. [1]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Embrapa Southeast Livestock, BR-13560970 Sao Carlos, SP - Brazil
[2] Univ Fed Sao Carlos, Dept Chem, Grp Appl Instrumental Anal, BR-13560970 Sao Carlos, SP - Brazil
[3] Sao Paulo State Univ, Dept Phys & Chem, Sao Paulo, SP - Brazil
Número total de Afiliações: 3
Tipo de documento: Artigo Científico
Fonte: Journal of Analytical Atomic Spectrometry; v. 28, n. 8, p. 1303-1310, 2013.
Citações Web of Science: 10
Resumo

Different conditions of extraction using water, a methanol-water mixture and nitric acid solutions were evaluated for speciation of As(III), As(V), DMA and MMA in plant samples that previously received As(V) after being sown and emergence was investigated. Microwave-assisted extraction (MAE) using diluted nitric acid solutions was also performed for arsenic extraction from chicken feed samples. The separation and determination of arsenic species were performed using HPLC-ICP-MS. The interference standard method (IFS) using Kr-83(+) as the IFS probe was employed to minimize spectral interferences caused by polyatomic species, such as (ArCl+)-Ar-40-Cl-35. The extraction procedures tested presented adequate extraction efficiencies (90%), and the four arsenic species evaluated were found in plant samples. Extractions with diluted nitric acid solution at 90 degrees C were the most efficient strategy, with quantitative recoveries for all four As species in plant tissues. On the other hand, the methanol-water mixture was the solvent with the lowest extraction efficiency (50-60%). For chicken feed samples, MAE at 100 degrees C for 30 min resulted in an extraction efficiency of 97% and only As(V) was found, without any species interconversion. The IFS method contributed to improving precision and limits of detection and quantification for all tested extraction procedures. Significant improvements on accuracy were obtained by applying the IFS method and recoveries between 77 and 94%, and 82 and 93% were obtained for plant extracts and chicken feed samples, respectively. (AU)

Processo FAPESP: 10/50238-5 - Determinacao de fosforo, enxofre e silicio em biodiesel usando espectrometro de massa acoplado ao plasma induzido com interface de colisao e reacao
Beneficiário:George Luis Donati
Modalidade de apoio: Bolsas no Brasil - Pós-Doutorado
Processo FAPESP: 06/59083-9 - Espectrometria de massa acoplada ao plasma induzido: aspectos fundamentais e aplicações
Beneficiário:Joaquim de Araújo Nóbrega
Modalidade de apoio: Auxílio à Pesquisa - Temático