Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do SciELO, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Importance of a distal proximal contact on load transfer by implant-supported single adjacent crowns in posterior region of the mandible: a photoelastic study

Texto completo
Autor(es):
Fabio Afranio de Aguiar Junior [1] ; Rodrigo Tiossi [1] ; Ana Paula Macedo [1] ; Maria da Gloria Chiarello de Mattos [1] ; Ricardo Faria Ribeiro [1] ; Renata Cristina Silveira Rodrigues [1]
Número total de Autores: 6
Afiliação do(s) autor(es):
[1] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Dent Mat & Prosthodont, BR-14040904 Ribeirao Preto, SP - Brazil
Número total de Afiliações: 1
Tipo de documento: Artigo Científico
Fonte: Journal of Applied Oral Science; v. 21, n. 5, p. 397-402, 2013-09-00.
Resumo

OBJECTIVE: This study aimed to evaluate the importance of a distal proximal contact on the load transfer to the posterior region of the mandible by non-splinted adjacent implant-supported crowns using photoelastic stress analysis. MATERIAL AND METHODS: A rectangular model (68x30x15 mm) was made of polymethylmethacrylate resin to simulate half of the mandibular arch. One model was completed with resin replicas representing the first premolar and second molar and with two 3.75 mm dia.x11 mm internal hexagon threaded implants replacing the second premolar and first molar. The other model was manufactured in the same way but without the second molar. Both models were duplicated using photoelastic resin. The roots of the teeth replicas were covered with a layer of polyether impression material to simulate the periodontal ligament. Two different vertical loads were applied to the crowns as follows: 1 - single static point load alternately applied to the crowns replacing the second premolar and first molar (50 N); 2 - simultaneous static point loads applied to both of the crowns replacing the second premolar and first molar (100 N). The resulting isochromatic fringe pattern in the photoelastic model was monitored and photographed. RESULTS: All loading conditions studied showed that the presence of the second molar has changed the load transmission and the pattern of stresses. CONCLUSION: Results showed that the presence of a second molar proximal contact can help minimize the stresses around the implants. (AU)

Processo FAPESP: 08/06960-8 - Análise fotoelástica das tensões em próteses sobre implantes/pilares UCLA com conexão em hexágono interno sob diferentes esquemas de carga oclusal estática.
Beneficiário:Fabio Afrânio de Aguiar Junior
Modalidade de apoio: Bolsas no Brasil - Mestrado