Busca avançada
Ano de início
Entree
(Referência obtida automaticamente do Web of Science, por meio da informação sobre o financiamento pela FAPESP e o número do processo correspondente, incluída na publicação pelos autores.)

Stress analysis in oral obturator prostheses over parallel and tilted implants: photoelastic imaging

Texto completo
Autor(es):
Pesqueira, Aldieris Alves [1] ; Goiato, Marcelo Coelho [2] ; dos Santos, Daniela Micheline [2] ; Nobrega, Adhara Smith [2] ; Haddad, Marcela Filie [2] ; Andreotti, Agda Marobo [2] ; Moreno, Amalia [2]
Número total de Autores: 7
Afiliação do(s) autor(es):
[1] Univ Sagrado Coracao, Fac Dent, Dept Oral Biol, Sao Paulo - Brazil
[2] Univ Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, Sao Paulo - Brazil
Número total de Afiliações: 2
Tipo de documento: Artigo Científico
Fonte: Journal of Biomedical Optics; v. 18, n. 10 OCT 2013.
Citações Web of Science: 3
Resumo

This study aimed to evaluate the stress distribution through the photoelastic method in implant-retained palatal obturators prostheses. Two photoelastic models with bucco-sinusal communication were fabricated, one model without implants and another with two parallel implants and one tilted in the molar region. A conventional obturator prosthesis and five implant-retained obturators dentures with different attachment systems were fabricated: OR, three individualized O-rings; BC, bar clip; BOC, implants splinted by bars associated with two O-rings positioned at the center of the bar; OD, implants splinted by bars associated with two O-rings positioned in distal cantilever; and BOD, implants splinted by bars with clips associated with two O-rings positioned in distal cantilever. Each assembly (model/attachment system/prosthesis) was positioned in a circular polariscope and a load of 100 N was applied on each implant. The results were obtained by observing the photographic record of the tensions in the photoelastic models resulting from the application of load. It can be observed that a larger amount of stress fringes on BC system. It was concluded that the attachment system has a direct influence on the stress distribution of implant-retained obturator prostheses, with the three individualized O-rings exhibiting the lowest stress values, and tilted implants presented a biomechanical behavior similar to parallel implants. (C) The Authors. (AU)

Processo FAPESP: 10/01241-3 - Análise fotoelástica de tensões em próteses obturadoras palatinas implanto-retidas, sobre implantes paralelos ou inclinados associados a diferentes tipos de sistemas de retenção
Beneficiário:Marcelo Coelho Goiato
Modalidade de apoio: Auxílio à Pesquisa - Regular